Device support
Programmers, coding boards, switches, NICs and other hardware
How do you break a 100G QSFP28 port on a FortiGate 1800F, 4200F or 4400F into four 25G subports with a QSFP28-to-4xSFP28 passive DAC, and why do the subports come up at the wrong speed?
An HPE FlexFabric 5950 48SFP28 8QSFP28 (JH402A) always downgrades an HPE JH419A 100G QSFP28 LC SWDM4 transceiver to 40G and never brings it up at full speed. Why?
An M290 with the optional two-port fibre module was fitted; can ports A0 and A1 be used as ordinary interfaces, for example for an ISP fibre handoff, and can a 1 Gb SFP be used in them?
What do the port states in the switchshow output of a Brocade Fibre Channel director or switch mean, and which of them point at the transceiver rather than the fabric?
A UCS 6332 fabric interconnect has only 40G QSFP+ ports, but the upstream switches are 10G. How can the FI be uplinked at 10G, and why does the breakout option not appear on some ports?
With auto-negotiation off and 10G configured on sfp1/sfp2 of a CCR1036-12G-4S (RouterOS 6.43.8), MikroTik S+DA0001 and Amphenol DACs still run at 1G and the Cisco side shows no link at 10G. Which part of this link should be checked first?
FS Box V2 is a firmware/coding tool kit for optical transceivers and DAC/AOC cables. It reprograms a module's compatibility code so it is accepted by a target switch platform, letting engineers adjust coding in the field or when a switch is upgraded to a version that no longer accepts the old code…
Some Cotsworks SFF fibre modules ship with invalid data in the first EEPROM bytes (physical ID, extended physical ID, connector type) and with checksums programmed before the fields were finalised, so the Linux phy/sfp driveer does not detect them as valid modules. A kernel fixup rewrites the three…
An ODI DFP-34X-2C2 GPON ONU SFP failed to advertise its 2500BASE-X capability because its EEPROM (or virtual EEPROM) did not provide correct speed information to the Linux sfp driver, so the interface did not run at the expected rate. A kernel patch adds a quirk to force the right speed. Hardware…
On a Banana Pi BPI-R4 running OpenWRT 24.10.0 an SFP module failed with kernel logs failed to read EEPROM: -ENXIO and warnings that the module was slow to respond. The internet still worked but the log filled with the error, and the poster was unsure whether it pointed to a faulty stick, a GPON…
On an Accton Wedge100BF-32x the ONLP call onlpsfpeepromread returned QSFP EEPROM data with alternating bytes skipped, so vendor strings appeared with every other symbol missing; the same transceiver read correctly on an Accton AS7312-54x. The vendor name FINISAR CORP appeared at the wrong offset…
Adapter boards that, with a serial programmer, read and write transceiver memory across SFP, SFP+, SFP28, SFP112, QSFP/QSFP+/QSFP28, SFP-DD, QSFP-DD, XFP and OSFP. The software covers the MSA/CMIS memory maps, manages host/manufacturer passwords including brute-force search, changes…
A user guide for an SNR SFP/SFP+ reprogramming solution: USB programmer plus Windows/Linux software (FTDI drivers required) supporting SFP and SFP+ per INF-8053, SFF-8472/8431, INF-8077i and INF-8438. The workflow is connect, read the module to display vendor/model/wavelength, load a new firmware…
A USB coding-board product line to reprogram optical transceivers so they match different equipment vendors. Supported form factors span GBIC, SFP, SFP+, SFP28, XFP, QSFP, QSFP28, QSFP-DD plus RJ45, DAC and AOC. The software reads, decodes, edits and writes module memory, ships about 400 well-known…
A used IBM Emulex dual-port 10GbE SFP+ PCIe card (bent bracket, loose heatsink) made both TrueNAS Core and a Windows 10 PC hang for a long time during boot; the switch showed a link but neither OS saw the interface as active. Hardware involved: IBM Emulex dual-port 10GbE SFP+, Chelsio NICs, Intel…
On an Alta Labs Route 10 the SFP+ ports recognised FS.com SFP-H10GB-CU2M and 10Gtek CAB-10GSFP-P2M DACs (which had worked on MikroTik CRS devices) but no link came up against a MikroTik CRS309-1G-8S+; forcing 1G baseT full gave a 1 Gbps link only. Staff requested diagnostics and ethtool -I output…
A Chelsio CC2-S320E-SR (110-1114-30) dual-port SFP+ card recognised by TrueNAS would not link to a Dell PowerConnect 6224 through a QSFPTEK 0.5 m passive DAC: no link lights and status: no carrier, even after assigning IPs to cxgb0/cxgb1. Looping the DAC between two switch ports worked, and looping…
On an inexpensive firewall appliance (Intel Atom C3758R, six 1GbE igc ports and two SFP+ cages wired to the CPU) OPNsense showed four ix interfaces instead of two and the SFP+ ports stayed red/down with a copper SFP+ RJ45 module, although the link LEDs lit. ifconfig -v identified ix0/ix1 as the…
Replacing an old Dell switch with an Extreme 5420M-24, the same SFP module that had worked in the Dell would not bring the network up: the uplink port was active with rising TX counters but RX stayed at zero, no DHCP address, no ping to the firewall, and a new SFP+ module behaved the same. Ethernet…
A FortiGate 500E displayed the message This port is using a third-party transceiver on an SFP+ port; the poster asked whta it meant and which SFP+ specification to use. There were no errors or link problems, only the log line, so the real question was whether it signals a fault, degrades support…
0votes
0comments
118views
Monitoring reported packet loss toward an ESXi iSCSI host; on the Dell S4810 (FTOS 9.11(2.6)) the interface TenGigabitEthernet 0/37 showed the warning Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M because a non-Dell DAC was used. The link was up with normal traffic (about 16…
4votes
2comments
152views
On Zyxel XGS4600 switches, 10G and 1G SFP+ transceivers (including an FS.com DWDM-SFP10G-80) intermittently stopped transmitting; only removing and reinserting the module restored the link. Transceiver statistics at that moment showed TX power -inf dBm, voltage at the 3.00 V low alarm and TX bias…
A T2600G-28TS (TL-SG3424) uplinked over fibre to another building using D-Link transceivers and media converters showed the SFP port UP and transmitting but never receiving packets. Restart, factory reset and other SFP ports were tried. Another user returned the switch after failing to link it to…
Cisco-compatible CWDM SFP modules that had worked in Dell PowerConnect 6024 and 6224 switches produced a transmit failure error in a PowerConnect 8024F, presumably because the 8024F ports are SFP+. The poster considered Finisar FWLF1524P2Vxx modules but wanted confirmation from someone with a…
After a complete power loss a Dell R740 with a four-port Broadcom NDC (2x SFP+, 2x 1GbE) booted normally but the fibre SFP+ modules stayed unpowered and disconnected; a reboot did not help and only physically removing and reinserting the modules restored them. Dell support pointed at drivers and…
0votes
0comments
109views
Between VxRail Dell S5212F-ON TOR switches and Cisco C9500-48Y4C switches, FS.com SFP28 DACs behaved inconsistently: a 5 m cable custom-coded Cisco on one end and Dell on the other came Line Up, Protocol down; a 2 m Cisco/Cisco-coded cable linked; a 3 m cable would not link even with the 2 m…
3votes
2comments
138views
A short no-name DAC between a UDM SE and a Minisforum MS-01 had worked for months; a new 30 m Ubiquiti UACC-AOC-SFP10-30M active optical cable was recognised by the UDM SE (vendor, part, serial, temperrature, power visible) but no link came up and the SFP port log showed an SFP EEPROM error; on…
The poster wanted to connect a UDM SE (10G SFP+) to an Enterprise XG 24 switch (25G SFP28) and asked whether an SFP+ DAC would work with the SFP28 port falling back to 10G, or whether an SFP28 DAC was preferable. The concern was whether the SFP28 cage would fall back to 10G with an ordinary SFP+…
2votes
2comments
111views
A UDM Pro (port 11 set to 1G) and a US-16-150W (port 17) connected by a 1 m Ubiquiti DAC (UDC-1) did not talk: the switch showed a link light, the UDM Pro showed nothing. Setting both sides to 1G and rebooting both devices did not help; reversing the cable and removing the parallel copper uplink…
3votes
2comments
107views
An ADDON JD097C-AO SFP+ DAC worked between two US-48-500W (firmware 3.3.11.3850) but not from a US-48-500W to a US-16-XG (3.7.39.6089): no link lights on either side and forcing 10G made no difference, although mca-dump on the XG showed the module fully parsed (sfpfound true, vendor ADDON, part…
On two sites a UNAS Pro (UniFi RJ45 SFP+ module) and a UNVR (UniFi fibre SFP+ module) dropped to 1G after every firmware update or power cycle; rebooting the device, the port or the switch did not help, only physically pulling and reinserting the module (or reseating the fibre) restored an…
A new UDM Pro replaced a USG-3; plugging its LAN SFP+ port into the free SFP port of a UniFi Switch 24 with a known-good SFP+ DAC (taken from a working switch-to-switch link) gave no link on either UDM Pro port, and manually setting the UDM Pro port to 1 Gbps did not help. Several other users…
2votes
2comments
144views
After UniFi Network 10.0.140 / switch firmware 7.2.123 several operators saw SFP+ ports (UI optics, UACC-OM-MM-10G-D, MikroTik XS+DA0001 DACs, UACC-CM-RJ45-MG copper modules) flapping on US-XG-16, USW Pro Max, UDM Pro and USW-24-Pro units, with STP State Flapping alerts, ports blocked, and switches…
0votes
0comments
172views
With a CSS326-24G-2S+ (SwOS 2.6) and a server with an Intel 82599 card, two different S+DA0001 DACs and two Intel cards never linked; two CSS326 switches connected by DAC only achieved 1 Gbps. A later reader on SwOS 2.12 with an 82599 reported the same. No solution was posted. Hardware involved…
Hi, I am looking for a solution for working with OSFP-XD 1.6 (and higher) transceivers. Your documentation states that CodingBox supports various hardware programmer solutions. Are there plans to develop a programmer for the XD format, and if so, what is the estimated timeframe for the…
Two Solid Optics SFP-H25GB-CU5M SFP28 DACs between a MikroTik CCR2004-1G-12S+2XS and an FS S5860-20SQ switch produced status: no-link on sfp28-1 and sfp28-2 with auto-negotiation off, 25 Gbps, full duplex, FEC91 and no flow control; RouterOS 7.8rc1 was tried on vendor advice. The modules were…
A CRS326-24G-2S+RM and a CCR1009-7G-1C-1S+PC connected with a MikroTik SplusDA0001 SFP+ DAC only linked at 1 Gbps; enabling 10G dropped the link, and the CRS326 in SwOS did not even offer a 10G option. The poster needed SwOS for harrdware LACP. RouterOS/SwOS updates, supout files, and a replacement…
A CSS326 (SwOS 2.12) uplinked to an RB4011 throuhg an FS.com 10G active DAC accumulated Rx MAC errors, Rx FCS errors and Tx pauses. Cleaning the DAC connectosr did not help, and the poster asked whether SwOS had SFP+ bugs. Hardware involved: MikroTik CSS326-24G-2S+, MikroTik RB4011, FS.com 10G…
SFP+ DACs linked MikroTik-to-MikroTik and OLT-to-OLT, but between a V-SOL EPON OLT 16008D and a CCR2004-1G-12S+2XS or CRS326-24G-2S+RM the OLT reported the interface as disconnected. The same DACs were recognised on both platforms, so the poster suspected a cross-vendor auto-negotiation or…
On a CRS226-24G-S2+RM (RouterOS 6.42.11 long-term) the SFP+ port stayed at no link, not running, slave after a power loss, while software reboots were fine; disabling and re-enabling the interface fixed it manually. The problematic module was a Huawei MA5671A GPON SFP, other SFPs behaved, and the…
Two FS.com 1G BiDi SFPs (1490/1310 and 1310/1490 nm) in a MikroTik CRS326-24G-2S+ running SwOS 2.9 detected incoming light around -6 dBm but never established a link; the same optics linked on a Netgear switch. The poster asked whether a manual speed setting was needed and whether RouterOS would…
FS.com 40 km 1550 nm SFP+ modules (item 11592) showed their information in a MikroTik CCR1016 but never linked in the SFP+ ports, whatever the auto-negotiation, 1G/10G speed or flow-control settings; standard 10G modules (item 29851) worked in the same ports, and the 40 km modules ran at 1G in…
2votes
2comments
118views
Used Intel 82599ES 10-Gigabit SFI/SFP+ NICs from eBay were connected with 10Gtek SFP+ DACs and, via QNAP switches, with 10Gtek SR transceivers over OM3. On Linux dmesg looped NIC Link is Up 10 Gbps / NIC Link is Down; on FreeBSD the interface showed no carrier and DHCP failed. allowunsupportedsfp=1…
With two dual-port Mellanox ConnectX-4 cards, a MikroTik SFP+ switch, 1 m OM4 patches and mixed 10G/25G transceivers from several vendors, one NIC port showed link UP but got no DHCP and could not route, 25G transceivers negotiated only 1G, and previously stable 10G links dropped intermittently…
Before deployment the poster asked for a certified or tested SFP28 DAC to connect an HPE FlexFabric 5950 with an SFP28 card to a dual-port Mellanox MCX4121A-ACAT (ConnectX-4 Lx), and for any documentation of that pairing. Hardware involved: HPE FlexFabric 5950, Mellanox MCX4121A-ACAT, SFP28 DAC…
We are handing a 100G circuit off to a core router through a leased optical transport system, and the port on our side refuses to come up. The same pair of modules links instantly on the bench, which is what makes this so irritating. Wedge100BF-32X (wedge100bf32x) running SONiC InnoLight…
Small homelab, two second-hand switches and a drawer of optics collected over the years, most of which the hosts refuse because of the vendor code. Recoding has always been the blocker: a proper programmer sits around 369 USD, which is more than I paid for the switches, and the Ubiquiti SFP Wizard…
I do industrial installs, mostly Hirschmann switches in cabinets nobody wants to open twice. On the last couple of projects the optics were the line item that hurt: the switches expect Hirschmann-coded modules, and the original M-SFP parts cost several times an equivalent generic module, with lead…
2votes
2comments
120views
We are moving the office uplinks from copper to fibre and the quote that came back has DrayTek-branded optics in every line. Before I start arguing about the difference against ordinary 10G modules I would like to know whether the hardware actually cares what sits in the cage, because the…
2votes
2comments
112views
I do small business installs, and this one is a fibre service handed off on an ADVA FSP 150-GE102Pro. The customer wants the WAN terminated on their own router instead of the carrier box, so it has to land in the SFP+ cage of a MikroTik RB4011iGS+. Nobody told me what fibre the service actually…