CodingBox Q&A Ask question

HPE FlexFabric 5945 with 100G QSFP28 BiDi (JQ344A): line protocol DOWN until firmware R6715

Asked Active Viewed 20 Original language: English
3

On a FlexFabric 5945 (JQ074A) running R6555, HPE JQ344A 100G QSFP28 BiDi transceivers give Line protocol state: DOWN both switch-to-switch and towards a server NIC (P25960-B21). The same ports link fiine with DAC cables, optical diagnostics show healthy power on all four lanes, and the moduls work when moved into the server NICs. Is this an autonegotiation issue?

Comments 2

The reported JQ344A BiDi combination did not operate on R6555, despite normal lane power and working DAC links. Upgrading the FlexFabric 5945 to R6715 resolved that case.

4 Indiawaverunner21IN Original (English)

Check the transceiver support notes for the Comware release as well as the hardware matrix. A module working in the server NIC does not prove that the switch's installed release impleemnts its optical mode correctly.

1 Vietnamlambdaeng12VN Original (English)
Log in to comment. Log in