CodingBox Q&A Ask question

netrunner

South Korea joined 7 months ago 10 questions 37 comments

Systems administrator from Daejeon. Mostly FS and generic modules.

Questions

1vote
2comments
69views

Z9332F SONiC 4x100G breakout: Intel DR4 QSFP-DD fails CMIS datapath with ConfigRejectedPartialDataPath, fixed by newer module revision

On a DellEMC Z9332F-O32 running SONiC master build using the CMIS manager a 400G Intel DR4 QSFP-DD module (SPTSHP2PMCDF) is broken out into 4x100G. All resulting 100G interfaces stay down although the module advertises both 400GAUI-8 and 100GAUI-2 applications. show interfaces transceiver status…

South Korea netrunner KR asked
2votes
1 answer
65views

OPNsense on a budget C3758R appliance: four ix interfaces, SFP+ ports show down with an RJ45 module

On an inexpensive firewall appliance (Intel Atom C3758R, six 1GbE igc ports and two SFP+ cages wired to the CPU) OPNsense showed four ix interfaces instead of two and the SFP+ ports stayed red/down with a copper SFP+ RJ45 module, although the link LEDs lit. ifconfig -v identified ix0/ix1 as the…

7votes
7comments
391views

Scripting DDM polling over I2C: which A2h bytes hold the live values and which the thresholds

I am writing a small poller that pulls temperature, voltage, bias and optical power straight off the modules on our whitebox boxes, so we get a trend line instead of someone eyeballing a link after it has already started erroring. The NOS prints pretty values, but I want the raw numbers with the…

1vote
1 answer
117views

Non-Juniper SFP+/SFP modules not detected in any port of an EX2300-24P but fine in an EX2300-48P

While staging an EX2300-48P and an EX2300-24P (both Junos 18.2R3-S5.3) with non-Juniper SFP+/SFP moules, the 48-port switch recognised the transceivers and created interfaces, but the 24-port switch showed nothing in any of its four uplink ports; show chassis hardware listed PIC 1 as 4x10G SFP/SFP+…