TL-SX3008F links at 1G instead of 10G behind a 2.5G router and an MC420L media converter
A TL-SX3008F on firmware 1.20.0 only ever shows the orange 1G LED on its SFP+ ports. The chain is an ER7412-M2 router with a 2.5G port, an MC420L media converter and SM5110-LR 10GBASE-LR modules; the link only comes up at all when 1G SM311LS modules are fitted, and the Omada controller reports 1000 Mbps. Why is 10G never negotiated?
Comments 2
The TL-SX3008F SFP+ ports support 1G and 10G, not a direct 2.5G optical mode. Installing LR optics does not by itself provide rate conversion for a 2.5G copper router port through the converter.
Separate the rate domains with suitable switching hardware that supports the required rate independently on each side. Verify the converter's actual supported modes rather than assuming that 10G optics make the entire chain negotiate at 10G.