CodingBox Q&A Ask question

Questions tagged “fibre-channel”

12 questions
15 30 50 per page
5votes
3comments
129views

IBM Power FC adapters: is the SFP its own FRU, and will IBM swap optics we did not buy from them

We run a couple of IBM Power boxes next to a small SAN, and I am trying to write down a sane spares policy before the next hardware maintenance renewal. The part I cannot pin down is the transceiver itself: on some adapters it looks like a field-replaceable part in its own right, on others a…

2votes
1 answer
167views

Brocade G610 on FOS 9.x faults compatible 16G SWL optics: Mod_Inv and Speed Mismatch / Incompatible SFP

We are adding capacity to a small FC fabric and bought compatible 16G short-wave SFP+ from an optics supplier instead of paying the switch vendor price. The switch refuses them. Brocade G610, Fabric OS 9.x generic-coded 16G SWL SFP+, correct wavelength and reach according to the label Brocade-coded…

5votes
1 answer
211views

Brocade 200e between Proxmox and FreeNAS: Buffer I/O error and isp0: Receive Error while all ports show online

Running a small virtualization setup: two Proxmox 6 nodes and a target on FreeNAS 11.2. While the HBAs were connected to the target directly, everything ran for months without a single error. Put a used Brocade 200e between them to avoid crossing cables, and that's when it started. two Proxmox 6…

3votes
1 answer
106views

Brocade G720 keeps every 64G SFP-DD port in Module_Invalid with the DD PoD licence applied

We inherited a pair of Connectrix DS-7720B (Brocade G720) for a new fabric, and I haven't got anywhere near zoning yet, because not one of the double density ports will come up. Every single one of them says the same thing in switchshow: What is in the rack: Connectrix DS-7720B / Brocade G720…