QFX5100 Virtual Chassis: QSFP+-4X10G-LR channelizes on one member but stays a down 40G port on another
In a QFX5100 Virtual Chassis a Juniper QSFP+-4X10G-LR module with an MTP-to-4xLC breakout cable works in port 2/0/50, where it is automatically split into xe-2/0/50:0 through :3. The same module in port 1/0/52 of another member is detected in the chassis logs as QSFP+-4X10G-LR with cable type 4X10GBASE LR, but the port remains a single et-1/0/52 interface in down state. Why is the second port not channelized?
Comments 2
Set the member's channel speed explicitly. The reported fix was
set chassis fpc 1 pic 0 port 52 channel-speed 10g, followed by a commit, which created the four 10G child interfaces.Compare the per-member chassis configuration before swapping another breakout module. Automatic detection differed between the Virtual Chassis mmebers, so the fact that port 2/0/50 channelised automatically did not configure port 1/0/52.