CodingBox Q&A Ask question

Questions tagged “DAC”

51 questions
15 30 50 per page
0votes
1 answer
82views

Alta Labs Route 10 SFP+ ports detect FS.com and 10Gtek DACs but never link; SR optics work at 10G

On an Alta Labs Route 10 the SFP+ ports recognised FS.com SFP-H10GB-CU2M and 10Gtek CAB-10GSFP-P2M DACs (which had worked on MikroTik CRS devices) but no link came up against a MikroTik CRS309-1G-8S+; forcing 1G baseT full gave a 1 Gbps link only. Staff requested diagnostics and ethtool -I output…

1vote
1 answer
54views

Chelsio S320E and a Dell PowerConnect 6224 over a QSFPTEK 0.5 m DAC: no carrier, cable works switch-to-switch

A Chelsio CC2-S320E-SR (110-1114-30) dual-port SFP+ card recognised by TrueNAS would not link to a Dell PowerConnect 6224 through a QSFPTEK 0.5 m passive DAC: no link lights and status: no carrier, even after assigning IPs to cxgb0/cxgb1. Looping the DAC between two switch ports worked, and looping…

0votes
0comments
118views

Dell Force10 S4810 warns Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M on a third-party DAC

Monitoring reported packet loss toward an ESXi iSCSI host; on the Dell S4810 (FTOS 9.11(2.6)) the interface TenGigabitEthernet 0/37 showed the warning Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M because a non-Dell DAC was used. The link was up with normal traffic (about 16…

2votes
2comments
111views

UDM Pro to US-16-150W over a 1 m Ubiquiti DAC: link light on the switch only, even with both ports forced to 1G

A UDM Pro (port 11 set to 1G) and a US-16-150W (port 17) connected by a 1 m Ubiquiti DAC (UDC-1) did not talk: the switch showed a link light, the UDM Pro showed nothing. Setting both sides to 1G and rebooting both devices did not help; reversing the cable and removing the parallel copper uplink…

3votes
2comments
107views

ADDON JD097C-AO DAC links two US-48-500W switches but not the US-16-XG, which still reads the cable EEPROM

An ADDON JD097C-AO SFP+ DAC worked between two US-48-500W (firmware 3.3.11.3850) but not from a US-48-500W to a US-16-XG (3.7.39.6089): no link lights on either side and forcing 10G made no difference, although mca-dump on the XG showed the module fully parsed (sfpfound true, vendor ADDON, part…

0votes
0comments
172views

CSS326-24G-2S+ and Intel 82599 NIC fail to link over an S+DA0001 DAC; switch-to-switch DAC only reaches 1G

With a CSS326-24G-2S+ (SwOS 2.6) and a server with an Intel 82599 card, two different S+DA0001 DACs and two Intel cards never linked; two CSS326 switches connected by DAC only achieved 1 Gbps. A later reader on SwOS 2.12 with an 82599 reported the same. No solution was posted. Hardware involved…

2votes
2comments
118views

Intel 82599ES with 10Gtek DACs and transceivers: link flaps up and down on Linux and FreeBSD

Used Intel 82599ES 10-Gigabit SFI/SFP+ NICs from eBay were connected with 10Gtek SFP+ DACs and, via QNAP switches, with 10Gtek SR transceivers over OM3. On Linux dmesg looped NIC Link is Up 10 Gbps / NIC Link is Down; on FreeBSD the interface showed no carrier and DHCP failed. allowunsupportedsfp=1…