Z9332F SONiC 4x100G breakout: Intel DR4 QSFP-DD fails CMIS datapath with ConfigRejectedPartialDataPath, fixed by newer module revision

Asked Active Viewed 69 Original language: English
1

On a DellEMC Z9332F-O32 running SONiC master build using the CMIS manager a 400G Intel DR4 QSFP-DD module (SPTSHP2PMCDF) is broken out into 4x100G. All resulting 100G interfaces stay down although the module advertises both 400GAUI-8 and 100GAUI-2 applications. show interfaces transceiver status shows CMIS state FAILED, every host lane reporting ConfigRejectedPartialDataPath, data paths deactivated, TX disabled on lane 1 and CDR loss of lock on all host lanes. xcvrd logs show repeated timeouts waiting for ConfigSuccess, retries 0-4, then CMIS: Ethernet152: FAILED. Is this an xcvrd CMIS manager bug or the transceiver?

Comments 2

Check the Intel module revision before assuming an xcvvrd bug. SPTSHP2PMCDF rejected the partial datapath configuration used for 4x100G, while the reported replacement QD4CS3LCCCR0PAM accepteed it.

0 United Statestxnode67US Original (English)

Compare the CMIS state and per-lane datapath flags with show interfaces transceiver status <port> and the EEPROM/DOM output. ConfigRejectedPartialDataPath identifies a different failure from absent optical power; advertising an application is not proof that every partial datapath arrangement is implemented.

1 GermanywavesmithDE Original (English)
Log in to comment. Log in