Z9332F SONiC 4x100G breakout: Intel DR4 QSFP-DD fails CMIS datapath with ConfigRejectedPartialDataPath, fixed by newer module revision
On a DellEMC Z9332F-O32 running SONiC master build using the CMIS manager a 400G Intel DR4 QSFP-DD module (SPTSHP2PMCDF) is broken out into 4x100G. All resulting 100G interfaces stay down although the module advertises both 400GAUI-8 and 100GAUI-2 applications. show interfaces transceiver status shows CMIS state FAILED, every host lane reporting ConfigRejectedPartialDataPath, data paths deactivated, TX disabled on lane 1 and CDR loss of lock on all host lanes. xcvrd logs show repeated timeouts waiting for ConfigSuccess, retries 0-4, then CMIS: Ethernet152: FAILED. Is this an xcvrd CMIS manager bug or the transceiver?
Comments 2
Check the Intel module revision before assuming an xcvvrd bug. SPTSHP2PMCDF rejected the partial datapath configuration used for 4x100G, while the reported replacement QD4CS3LCCCR0PAM accepteed it.
Compare the CMIS state and per-lane datapath flags with
show interfaces transceiver status <port>and the EEPROM/DOM output.ConfigRejectedPartialDataPathidentifies a different failure from absent optical power; advertising an application is not proof that every partial datapath arrangement is implemented.