CodingBox Q&A Ask question

nethawk74

Egypt joined 1 year ago 11 questions 13 comments

ISP field engineer from Alexandria. Mostly Arista and Mellanox.

Questions

2votes
2comments
22views

ConnectX-4 in InfiniBand mode: OpenSM reports PORT_DOWN and the SB7700 shows Unknown cable - the DAC was Ethernet-only

Two servers with dual-port ConnectX-4 VPI cards (CX456A, firmware 12.14.2036) connected back-to-back with copper cables run at about 100 Gb/s in Ethernet mode, but after switching the ports to InfiniBand OpenSM 4.6.1 loops with "Got invalid base LID 65535 from the network" and "SM port is down"…

Egypt nethawk74 EG asked
0votes
1 answer
57views

Writing to password-protected SFP/QSFP/XFP: where the password lives and how brute force works

Users needed to write to password-protected SFP/QSFP/XFP modules from HP, Cisco, Finisar and JDSU. The thread documents the two protection levels: a host/user password protecting the user-writable area (A2h offset 7Bh on SFP, A0h offset 7Bh on QSFP/XFP) and a manufacturer password protecting the…

2votes
2comments
112views

Meraki MX95 WAN2 SFP will not link to an Extreme switch (but does to Netgear): power cycle after inserting the SFP

A Meraki MX95's WAN2 SFP would not link to an upstream Extreme switch, while the same SFP and patch linked to a Netgear switch, which in turn linked to the Extreme. The same happened with an MX85 against an AT&T-provided Ciena device. Cisco-certified and Extreme-certified SFPs were tried in all…

Egypt nethawk74 EG asked
0votes
0comments
83views

Wedge100BF-32X on SONiC: 100G LR4 links back to back but not through the transport unless TX is patched first

We are handing a 100G circuit off to a core router through a leased optical transport system, and the port on our side refuses to come up. The same pair of modules links instantly on the bench, which is what makes this so irritating. Wedge100BF-32X (wedge100bf32x) running SONiC InnoLight…

2votes
1 answer
87views

Synology RS3614xs+ with an Intel X520-DA2: allow_unsupported_sfp ignored until set in the DSM-specific modules.conf keys

A Synology RS3614xs+ with a supported Intel X520-DA2 rejected the wrongly ordered SFP+ modules as unsupported. Putting options ixgbe allowunsupportedsfp=1 into /etc/modules.conf had no effcet, and even when the kernel log showed ixgbe: allowunsupportedsfp Enabled the driver still reported failed to…

4votes
3comments
125views

Napatech capture SmartNICs: what actually happens with an SFP+ that is not in the qualified list

We run packet capture on a handful of Napatech cards and I am putting together the optics order for the next rack. Before spending anything I want to understand what the qualified module list actually means in practice, because the wording leaves room for interpretation. Napatech NT40E3 and NT20E3…