Third-party 100G DACs on QFX5200-32C: accepted as long as the cable EEPROM is Juniper-compatible

Asked Active Viewed 12 Original language: English
3

Can third-party 100GbE DACs connect QFX5200-32C switches to an all-flash storage array without a vendor block? Which EEPROM compatibility and exact-pairing checks are needed before production use?

Comments 2

The referenced guidance does not describe a blanket ban on third-party 100G DACs for QFX5200. The EEPROM coding and actual cable implementation still need to be compatible with both endpoints.

1 Egyptnetadmin16EG Original (English)

Use the validated HCT combinations where possible. For an unlisted cable, test the exact cable revision and switch/array firmware before rollout; a supplier's generic Juniper-compatible label is weaker evidence than that complete pairing test.

3 United Arab Emirateslambdahawk88AE Original (English)