2votes
1 answer
34views

Cisco doc: troubleshooting an unsupported transceiver in a Catalyst 3850 network module

Cisco troubleshooting document: inserting certain SFPs (for example GLC-SX-MMD or third-party modules) into a Catalyst 3850 C3850-NM sub-module produces %PLATFORMPM-6-MODULEERRDISABLE: The inserted SFP module ... is not supported and %PM-4-ERRDISABLE: gbic-invalid ... putting ... in err-disable…

2votes
1 answer
100views

Cisco module signature: bytes 96-127 must match the serial number or a recoded SFP is rejected

Discussion of why re-coded modules fail Cisco validation: Cisco SFPs carry a unique signature tied to each serial number in bytes 96-127, and editing vendor name or serial makes the signature no longer match, so the switch rejects the module unless the signature is regenerated. Hardware involved…

0votes
0comments
151views

Intel X710 in a Dell R740xd links with 2013 Cisco DACs (VID V02) but not 2019 ones (V03) of the same part number

Dell R740xd servers with OEM Intel X710 adapters were cabled to Cisco switches with SFP-H10GB-CU5M and SFP-H10GB-CU3M DACs. Two cables linked, five did not; the working ones carried a blank or V02 version ID (made 2013), the failing ones V03 (made 2019), all identified as SFP-10GBase-CX1 on the…

0votes
0comments
109views

Dell S5212F-ON to Cisco C9500-48Y4C: dual-coded FS SFP28 DACs stay protocol down while 2 m Cisco/Cisco cables link

Between VxRail Dell S5212F-ON TOR switches and Cisco C9500-48Y4C switches, FS.com SFP28 DACs behaved inconsistently: a 5 m cable custom-coded Cisco on one end and Dell on the other came Line Up, Protocol down; a 2 m Cisco/Cisco-coded cable linked; a 3 m cable would not link even with the 2 m…

2votes
1 answer
109views

MikroTik CSS610 to Cisco Nexus 5596: transceivers detected, no link, four bad fibre patch cords

A MikroTik CSS610-8P-2S+ (SwOS Lite) needed to connect its SFP+ ports to a Cisco Nexus 5596UP. The ports showed the transceivers in the web UI but no link, after trying several fibre cables and transceivers. The switch web UI listed vendor and type for each module, yet the port stayed at no-link…