CodingBox Q&A Ask question

ICX 6610: 'optics <-> speed mismatch. Replace with SFP+ to enable link' after speed-duplex 10g-full

Asked Active Viewed 130 Original language: English
3

While configuring the SFP+ ports 1/3/1-1/3/8 of a Brocade ICX 6610 for 10 Gbps with speed-duplex 10g-full, the switch answers "optics <-> speed mismatch. Replace with SFP+ to enable link" and the port stays down. What is it complaining about?

Comments 2

Check the inserted cable or optic before changing the licence again. speed-duplex 10g-full requests a 10G link, and a gigait-only module cannot satisfy it.

0 SpainoptictechES Original (English)

Use a supported 10G SFP+ cable or optic for 10G. If the attached equipment is actually gigabit, the documented lower-speed configuration is speed-duplex 1000-full-master. The port's requested rate and the module's rate must agree.

0 Netherlandsoptichub40NL Original (English)