CodingBox Q&A Ask question

MCP1650-V003E26 200G DAC on ConnectX-6 VPI: only 80-97 Gb/s and mlxcables reports QSFP28

Asked Active Viewed 52 Original language: English
3

Two MCX653106A-HDA ConnectX-6 VPI adapters, firmware 20.28.1002, use an MCP1650-V003E26 3 m 200GbE DAC in Ethernet mode. iperf measures 80-97 Gb/s and mlxcables prints QSFP28 rather than QSFP56. Does that identifier mean the cable has fallen back, and which link-state and host checks distinguish the causes?

Comments 2

The QSFP28 string is not proof that this QSFP56 DAC has fallen back. NVIDIA explained that those module families share the EEPROM identifier used by the utility.

4 United StatesedgewolfUS Original (English)

Check negotiated link state, adapter configuration and host throughput separately. A single iperf reesult can be limited by the hosts; inspect the actual link rate and test suitable parallel streams before diagnosing the cable from its identiifier text.

0 VietnamdwdmpilotVN Original (English)
Log in to comment. Log in