CodingBox Q&A Ask question

Questions tagged “tp-link”

13 questions
15 30 50 per page
2votes
1comment
52views

TP-Link TL-SM311LM to a SkyLane SFP in a Netgear GS716T: TP-Link side up, Netgear side down, 1 Mbps throughput

A TP-Link T1700G-28TQ (V3, firmware 3.0.0) with a TL-SM311LM module was linked to a Netgear ProSafe GS716T with a SkyLane SFP85P55GE0B989 module. The TP-Link port showed 1000M with a flashing LED while the Netgear port stayed down, and throughput was about 1 Mbps; with a media converter the link…

1vote
2comments
80views

TP-Link T2600G-28TS SFP port shows UP but receives nothing over fibre to D-Link converters; firmware update fixed it

A T2600G-28TS (TL-SG3424) uplinked over fibre to another building using D-Link transceivers and media converters showed the SFP port UP and transmitting but never receiving packets. Restart, factory reset and other SFP ports were tried. Another user returned the switch after failing to link it to…

China sfpnode CN asked
3votes
1 answer
73views

Aruba 2540 uplink ports 51-52 stay Down on an inter-building run while a 2530 links the same modules

I look after a two-building site and the access switches were replaced with Aruba 2540s a while back. The fibre between the buildings has not been touched, but since the swap the uplink refuses to come up. Aruba 2540 on our side, ports 51 and 52 used for the uplinks Aruba J4858D 1000SX in the 2540…