CodingBox Q&A Ask question

coreguru

Spain joined 3 months ago 8 questions 18 comments

Optical transport specialist from Valencia. Mostly Arista and Mellanox.

Questions

1vote
1 answer
141views

10Gtek ASF-GE-T copper SFPs stop linking on a CRS309 after RouterOS 7.14 because of a wrongly programmed EEPROM

After upgrading a CRS309-1G-8S+IN from RouterOS 6.48.6 to 7.14.1 (and 7.15beta8), ports 5 and 7 with 10Gtek ASF-GE-T (FTRJ8519P1BNL-PT) copper SFPs showed sfp-rx-loss: yes and no-link when auto-negotiation was enabled; disabling auto-negotiation and forcing 1G full duplex restored the link…

1vote
1 answer
310views

XCP-ng with X520-DA2 and Finisar SFP+: allow_unsupported_sfp must be set per port on the kernel command line

An XCP-ng host with an Intel X520-DA2 and Finisar SFP+ transceivers logged failed to load because an unsupported SFP+ or QSFP module type was detected. insmod with allowunsupportedsfp=1 failed with Unknown symbol in module; options ixgbe allowunsupportedsfp=1 in /etc/modprobe.d/ixgbe-options.conf…

2votes
1 answer
219views

Genuine SFP-10G-SR modules identified as 'GE ZX' and non-functional in Catalyst C9500-48Y4C

The poster's Cisco Catalyst C9500-48Y4C switches (IOS XE 16.12.04 after an upgrade) refuse to work with a batch of genuine Cisco SFP-10G-SR modules (VID V03, serials AVD2231D3TE and AVD2231D3RW): 'show inventory' lists them as 'GE ZX' instead of 'SFP+ 10GBASE-SR' and the ports stay non-functional…

4votes
1 answer
112views

Catalyst 3750-X C3KX-NM-10G module reports GLC-SX-MMD as 'Not Present' in some slots

Two Cisco Catalyst 3750-X switches (WS-C3750X-24P-L and WS-C3750X-48P-L) run identical code. A Cisco GLC-SX-MMD is detected normlly in Gi1/1/1 of the first switch, but the second switch reports 'media type is Not Present' with 'link type is force-up' on Gi1/1/1, and 'show idprom interface Gi 1/1/1'…