CodingBox Q&A Ask question

rxadmin25

Spain joined 6 months ago 12 questions 19 comments

Datacenter technician from Valencia. Mostly ISP backbone.

Questions

2votes
2comments
19views

Brocade G620 V2 (DS-6620B-V2): long-wave ISL stays down, the 10 km SFP+ 57-1000115-01 is qualified only for the original G620

An ISL between two DS-6620B-V2 switches over long-wave optics will not come online: switchshow shows "Speed Mismatch / Incompatible SFP", sfpshow says "Media invalid" and the log has C5-1001 "faulted due to invalid SFP, conflicting speed or laser fault". The modules were taken from an older…

Spain rxadmin25 ES asked
1vote
1comment
52views

Cannot write to Finisar SFPs with REVELPROG: manufacturer password protection and per-power-up entry

The poster could read and write OEM SFP variants with a REVELPROG and SFP adapter but not three Finisar references, suspecting manufacturer password protection. Finisar only documents the MSA user-EEPROM password in datasheets, not the proprietary manufacturer password, and the same happened with…

2votes
1 answer
105views

OPNsense 22.7: interface is disabled due to unsupported sfp on a 10G port, and the Linux ixgbe tunable does not apply

After upgrading OPNsense from the 21.x series to 22.7 a 10G SFP+ port stopped working with interface is disabled due to unsupported sfp; the newer Intel driver actively disables unrecognised modules. The poster tried to set ixgbe.allowunsupportedsfp=1 as a system tunable, which was not accepted…

0votes
1comment
64views

Genuine versus third-party SFP/SFP+ on Extreme switches: DDMI not readable on an X620, no vendor support

The poster had free thrid-party SFP/SFP+ samples that worked on Extreme switches and asked whether to buy genuine or third-party modules. A respondent reported that on a new X620 a third-party SFP+ linked but its DDMI data could not be read, and that Extreme provides no help for problems involving…

2votes
1 answer
100views

Connecting a UDM SE 10G SFP+ port to an Enterprise XG 24 SFP28 port: which DAC, and the mixed-speed limitation

The poster wanted to connect a UDM SE (10G SFP+) to an Enterprise XG 24 switch (25G SFP28) and asked whether an SFP+ DAC would work with the SFP28 port falling back to 10G, or whether an SFP28 DAC was preferable. The concern was whether the SFP28 cage would fall back to 10G with an ordinary SFP+…

1vote
1 answer
144views

Proxmox VE 6: X520-DA2 fails to load because an unsupported SFP+ or QSFP module type was detected

On Proxmox VE 6.0 (kernel 5.0.18-1-pve, ixgbe 5.1.0-k) an Intel X520-DA2 exposed ens1f0/ens1f1 but any inserted thirrd-party SFP+ module produced failed to load because an unsupported SFP+ or QSFP module type was detected, and the driver had to be reloaded to detect module changes at all. Hardware…

3votes
1 answer
158views

Enabling third-party SFPs on an Aruba 2530-48G-2SFP+: allow-unsupported-transceiver from 16.02.0013

An Aruba/HPE 2530-48G-2SFP+ on firmware 16.01.0012 logged Port contains a transceiver not made by Hewlett Packard Enterprise with the advice to use onlly genuine transceivers, and refused the modules; ironically one of the rejected transceivers was HP-branded. The poster asked whether a command…

1vote
1 answer
97views

Real incidents caused by third-party optics: slow I2C crashing a linecard and a DDM uptime overflow bug

In a NANOG discussion about vendor lock-in, an operator described two concrete failures. First, a third-party optic answered I2C reads too slowly; the switch vendor's polling code did not handle the timeout and crashed the linecard control plane, and the vendor refused to treat it as a bug because…