CodingBox Q&A Ask question

25G SFP28 links only on the stack master until FEC is matched (5420 stack to VSP 7432)

Asked Active Viewed 68 Original language: English
0

In a Universal 5420 EXOS stack ulinked to VSP 7432 switches over a 100G-to-4x25G breakout, port 1:52 on the master comes up but the matching port 2:52 on the backup unit stays down in the same LAG. 1G, 10G and 25G DAC links are fine. What is different about the 25G fibre link on the standby slot?

Comments 2

Compare operational FEC on the two stack members and the VSP peer. The reported asymmetry between the master and standby slots was a FEC issue rather than proof that the standby optic was bad.

1 United StateslasernodeUS Original (English)

Set both ends to a mutually supported FEC mode and recheck the operational state. A successful 10G or DAC test does not establish that a 25G optical link is using the same FEC settings.

0 Ukrainerxnode71UA Original (English)
Log in to comment. Log in