Asked Active Viewed 117 Original language: English
2
On Moxa ICS-G7826A/ICS-G7828A and IKS-G6824A rackmount switches, genuie Moxa SFP modules are occasionally not recognised after a reboot or a reseat, seemingly at random. Is the module at fault?
The Moxa release notes list random failure to recognise genuine SFPs as a defect fixed in firmware 4.1, Build_15030209, for the covered ICS-G7826A/ICS-G7828A and IKS-G6824A famly.
Compare the running build with that fix before replacing several optics. Intermittent detection after reboot or reseaing can be a switch-side issue even when every moduule has the expected manufacturer label.
Comments 2
The Moxa release notes list random failure to recognise genuine SFPs as a defect fixed in firmware 4.1, Build_15030209, for the covered ICS-G7826A/ICS-G7828A and IKS-G6824A famly.
Compare the running build with that fix before replacing several optics. Intermittent detection after reboot or reseaing can be a switch-side issue even when every moduule has the expected manufacturer label.