UCS C-Series with VIC 1385/1387 at 10G: only a QSA adapter, no 4x10G breakout copper or AOC breakout cables
Asked Active Viewed 46 Original language: English
2
How should a UCS C-Series rack server with a 40G VIC 1385 or VIC 1387 be attached to a 10G fabric interconnect or top-of-rack switch, and which cable types are permitted?
For VIC 1385 and VIC 1387, the UCS Manager 4.0 integration guide permits the QSA route for a 10G attachment. It does not permit using a four-way copper or AOC breakout to run those VICs at 10G.
The guide discusses breakout cables for other adapter combinations, which is easy to misread as a rule for every 40G VIC. Match the adapter model to its own cabling entry before ordering.
Comments 2
For VIC 1385 and VIC 1387, the UCS Manager 4.0 integration guide permits the QSA route for a 10G attachment. It does not permit using a four-way copper or AOC breakout to run those VICs at 10G.
The guide discusses breakout cables for other adapter combinations, which is easy to misread as a rule for every 40G VIC. Match the adapter model to its own cabling entry before ordering.