Optical transport specialist from Da Nang. Mostly SAN fabrics.

Questions

0votes
0comments
45views

IBM Emulex dual-port 10GbE SFP+ card hangs TrueNAS and Windows at boot and never shows an active link

A used IBM Emulex dual-port 10GbE SFP+ PCIe card (bent bracket, loose heatsink) made both TrueNAS Core and a Windows 10 PC hang for a long time during boot; the switch showed a link but neither OS saw the interface as active. Hardware involved: IBM Emulex dual-port 10GbE SFP+, Chelsio NICs, Intel…

3votes
2comments
88views

CCR1036-8G-2S+ shows link OK with 1G SFPs but passes no data; the same modules work on a CCR1036-12G-4S

A MikroTik CCR1036-8G-2S+ with S-31DLC20D 1.25G single-mode SFPs reported link OK but no traffic flowed; TX power was blank and RX was -9 dBm. The identical module on the same fibre worked in a CCR1036-12G-4S. Port disable/enable, forcing 1G full duplex on both ends and support tickets did not…

2votes
1 answer
48views

1G SFP on Intel X710 (pfSense, ixl) fails with unqualified module until the optic is recoded as Intel

On a Protectli Vault 6 with Intel X710 SFP+ ports (ixl0/ixl1) a 1G EZConn ETB43315-7S34-FR SFP showed no carrier. Logs contained Invalid advertised speed; valid flags are: 0x06, ixl1setlink: Error getting phy capabilities -37, aq error: 8 and Link failed because an unqualified module was detected!…

6votes
3comments
62views

Finisar FCLF8521P2BTL 1000BASE-T SFP rejected by Intel X710-DA2 despite feature matrix listing

The poster wanted to use a Finisar FCLF8521P2BTL 1000BASE-T copper SFP in an Intel X710-DA2 running NVM 7.1. Intel's X710/XXV710/XL710 Feature Support Matrix (rev. 3.4, Nov 2019, doc 332191-024) lists single-speed SFP 1GBASE-T transceivers with support limited to Finisar FCLF-8521-3, Kinnex A…