QFX5200-32C: QSFP-100G-PSM4 will not channelize into 4x10G, only 100G or 4x25G

Asked Active Viewed 20 Original language: English
2

On a QFX5200-32C the user inserted a QSFP-100G-PSM4 (the datasheet says each lane can run 1G/10G/25G) and set channel-speed 10g, but the switch kept a single 100G interface. Channelizing the same port to 4x25G worked, mixing speeds did not. How to get 4x10G out of this optic?

Comments 2

For this QFX5200/PSM4 combination, the referenced compatibility data supports 100G or 4x25G, not 4x10G. A module's lane-rate description does not guarantee that every rate is implemented by the host platform.

2 Türkiyedwdmops44TR Original (English)

Use an appropriate qualified 4x10G optic or cable for a four-way 10G design. A single-lane QSA approach on a different QFX modeel is a separate configuration and cannot be assumed to enable four 10G lanes herre.

2 SpainoptictechES Original (English)