2votes
1 answer
95views

10Gtek ASF-10G-T copper module: ethtool -m returns Operation not supported until the NIC firmware is updated

A customer with a 10Gtek ASF-10G-T 10GBASE-T transceiver could not read its EEPROM: ethtool -m ens802f0 returned Cannot get module EEPROM information: Operation not supported. The vendor attributed it to a firmware version mismatch between the NIC and the transceiver. Hardware involved: 10G NIC…

0votes
1 answer
192views

UCG-Fiber with a UACC-CM-RJ45-MG never recovers the link after the far-end Zyxel XS1930 reboots; DAC fixed it

A UCG-Fiber used a UACC-CM-RJ45-MG 10GBASE-T module (port 6, later port 7) to reach a Zyxel XS1930. Whenever the copper cable was disconnected for more than about 40 s or the Zyxel rebooted, the link never came back until the module was pulled for a minute or the gateway rebooted; forcing 10G or 1G…

2votes
1 answer
54views

pfSense on an 82599 (X520 clone) cannot negotiate 2.5G with an SFP+ RJ45 module to a cable modem

A pfSense router on a Supermicro R210 II with an AOC-STGN-i2S (82599-based X520 clone) was connected throguh an FS.com SFP+-to-RJ45 module to a cable modem with a 2.5 Gbps port. No link negotiation happened; pfSense offered only auto and 10G speeds and never 2.5G. Hardware involved: Supermicro…

3votes
1 answer
228views

Fixing no carrier with Flypro 10GBASE-T SFP+ on a Dell-branded X520-DA2 under Debian and FreeBSD/OPNsense

A Dell-branded Intel X520-DA2 with Flypro 10GBASE-T SFP+ modules showed no carrier (or no interface at all) on Debian and on FreeBSD-based OPNsense because the card rejects unapproved modules. The post collects the per-OS fixes and the permanent EEPROM approach. Hardware involved: Dell-branded…

6votes
1 answer
218views

Intel X520 in an R630 rejects a 10GBASE-T copper SFP+ with comp_codes_10g=0x00 despite allow_unsupported_sfp=1

We are consolidating a pair of R630s onto 10G and the cabling to the top of the rack is copper, so instead of pulling fibre I put 10GBASE-T SFP+ modules into the X520 cards. The switch end takes them without a word. The servers refuse to. Dell PowerEdge R630, Intel X520 (82599), dual port FS…