SonicWall TZ670 SFP+ port speed: the same 02-SSC-1874 module runs at different rates on different TZ models

Asked Active Viewed 36 Original language: English
2

A multi-rate SonicWall SFP+ module (02-SSC-1874) is moved between TZ280, TZ380/480/580 and TZ670 firewalls and negotiates different speeds; the port never reaches 10G on the smaller boxes. Is the module faulyt?

Comments 2

Check two separate limits: the firewall port's supported rates and the rate allowed for module 02-SSC-1874 on that model. Moving a multi-rate module does not override eitheer limit.

0 South KoreanetrunnerKR Original (English)

The referenced note lists different limits across the TZ families and a 5G limit for that module on several newer models. Use the exact platform/module entry; a TZ670 cage capable of 10G does not imply that every supported copper module will run at 10G there.

0 IndiasfpopsIN Original (English)