Asked Active Viewed 19 Original language: English
2

An ISL between two DS-6620B-V2 switches over long-wave optics will not come online: switchshow shows "Speed Mismatch / Incompatible SFP", sfpshow says "Media invalid" and the log has C5-1001 "faulted due to invalid SFP, conflicting speed or laser fault". The modules were taken from an older DS-6620B where they worked. Why does the V2 refuse them?

Comments 2

The original G620 and G620 V2 have different qualification entries. The 57-1000115-01 long-wave module used in the older DS-6620B is not the qualified part for DS-6620B-V2.

1 United Kingdomedgewolf34GB Original (English)

The replacement identified for that V2 csae is Dell 100-652-961 / Brocade 57-1000493-01. Check the hardware revision as well as the marketing model before moving optics between switches.

3 Argentinaportbear20AR Original (English)