CodingBox Q&A Ask question

Questions tagged “Extreme”

10 questions
15 30 50 per page
2votes
2comments
112views

Meraki MX95 WAN2 SFP will not link to an Extreme switch (but does to Netgear): power cycle after inserting the SFP

A Meraki MX95's WAN2 SFP would not link to an upstream Extreme switch, while the same SFP and patch linked to a Netgear switch, which in turn linked to the Extreme. The same happened with an MX85 against an AT&T-provided Ciena device. Cisco-certified and Extreme-certified SFPs were tried in all…

Egypt nethawk74 EG asked
0votes
1comment
64views

Genuine versus third-party SFP/SFP+ on Extreme switches: DDMI not readable on an X620, no vendor support

The poster had free thrid-party SFP/SFP+ samples that worked on Extreme switches and asked whether to buy genuine or third-party modules. A respondent reported that on a new X620 a third-party SFP+ linked but its DDMI data could not be read, and that Extreme provides no help for problems involving…

4votes
1 answer
88views

Single fiber between buildings: how to link a 1G SFP on an Avaya VSP 4400 to an SFP+ port on an Extreme X690

Joining two campus buildings into one network. In building A there's an Avaya VSP 4400, and only 1G SFP ports are free there: the dedicated uplinks have long been taken for other purposes. In building B there's an Extreme Summit X690-48x-2q-4c, and there only 10G SFP+ ports are free, no other…

Russia wavetech RU asked