TL-SG3428 V2 firmware 2.0.3 keeps SFP TX_Disable asserted: link up but no traffic

Asked Active Viewed 66 Original language: English
2

After updating a TL-SG3428 V2 to firmware 2.0.3 Build 20210409 Rel.52950, Skylane Optics SBU35020DR3D SFP modules stop passing data: the switch reports the link as up while the module transmitter stays off with the TX_Disable pin permanently active. No-name 1000FD copper SFPs thaat had worked before also stopped, and DDM stopped reporting. The same firmware generation behaves correctly on the TL-SG3428X variant.

Which part of this link should be checked first?

Comments 2

The reported regression in 2.0.3 Build 20210409 left TX_Disable asserted and also affected diagnostics. The later reported working image was 2.0.7 Build 20220606 Rel.58990.

4 GermanytxhubDE Original (English)

Verify hardware revision and image compatibility with TP-Link before updating. The historical working image was found under a related variant, which is a reason to obtain confirmation, not permission to cross-flash arbitrary sibling-model firmware.

4 RussiadwdmmonkRU Original (English)