A 10GbE converged network adapter in an IBM System x server with a third-party Twinax/DAC cable or SFP+ shows a flapping link and the port LEDs stay dark. Is the cable defective?

Comments 2

Check the complete adapter feature and cable part number against the IBM support matrix. The supported set differs across the Brocade, Emulex and QLogic converged adapters.

4 CanadalantechCA Original (English)

The matrix distinguishes active Twinax, passive DAC and optics. A dark LED or flapping link with an unlisted cable is a reason to repeat the test wih a validated part, not sufficient evidence that the adapter or cable is physically broken.