2votes
1 answer
34views

Cisco doc: troubleshooting an unsupported transceiver in a Catalyst 3850 network module

Cisco troubleshooting document: inserting certain SFPs (for example GLC-SX-MMD or third-party modules) into a Catalyst 3850 C3850-NM sub-module produces %PLATFORMPM-6-MODULEERRDISABLE: The inserted SFP module ... is not supported and %PM-4-ERRDISABLE: gbic-invalid ... putting ... in err-disable…

0votes
1 answer
18views

Huawei S6700 iStack fails because different transceiver types are mixed on the stacking ports 45-48

A Huawei S6700 iStack did not form because the optical modules on the dedicated stacking ports 45-48 were of different types; the platform requires identical transceivers on those ports. The four ports 45-48 are the fixed stacking ports, and mixing, for example, an SR module on one and an LR module…

0votes
1 answer
21views

Huawei 25GE ports: 10G SFP+ and short copper cables need RS-FEC enabled or the interface stays down

On Huawei switches with 25GE ports the poster asked about using SFP+ transceivers and copper cables; per the troubleshooting docs, when a non-1 m copper cable is connected to a 25GE interface the RS-FEC function must be enabled or the interface goes Down, and mixing different optical modulles at…

2votes
1 answer
100views

Cisco module signature: bytes 96-127 must match the serial number or a recoded SFP is rejected

Discussion of why re-coded modules fail Cisco validation: Cisco SFPs carry a unique signature tied to each serial number in bytes 96-127, and editing vendor name or serial makes the signature no longer match, so the switch rejects the module unless the signature is regenerated. Hardware involved…

0votes
0comments
118views

Dell Force10 S4810 warns Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M on a third-party DAC

Monitoring reported packet loss toward an ESXi iSCSI host; on the Dell S4810 (FTOS 9.11(2.6)) the interface TenGigabitEthernet 0/37 showed the warning Non-qualified pluggable media present, SFP+ type is 10GBASE-CU2M because a non-Dell DAC was used. The link was up with normal traffic (about 16…

0votes
0comments
151views

Intel X710 in a Dell R740xd links with 2013 Cisco DACs (VID V02) but not 2019 ones (V03) of the same part number

Dell R740xd servers with OEM Intel X710 adapters were cabled to Cisco switches with SFP-H10GB-CU5M and SFP-H10GB-CU3M DACs. Two cables linked, five did not; the working ones carried a blank or V02 version ID (made 2013), the failing ones V03 (made 2019), all identified as SFP-10GBase-CX1 on the…

1vote
2comments
79views

TP-Link T2600G-28TS SFP port shows UP but receives nothing over fibre to D-Link converters; firmware update fixed it

A T2600G-28TS (TL-SG3424) uplinked over fibre to another building using D-Link transceivers and media converters showed the SFP port UP and transmitting but never receiving packets. Restart, factory reset and other SFP ports were tried. Another user returned the switch after failing to link it to…

0votes
0comments
54views

Cisco-compatible CWDM SFPs that worked in PowerConnect 6024/6224 report transmit failure in an 8024F

Cisco-compatible CWDM SFP modules that had worked in Dell PowerConnect 6024 and 6224 switches produced a transmit failure error in a PowerConnect 8024F, presumably because the 8024F ports are SFP+. The poster considered Finisar FWLF1524P2Vxx modules but wanted confirmation from someone with a…