CodingBox Q&A Ask question

Suppliers and vendors

Experience with suppliers, third-party modules, warranty and pricing

19 questions
15 30 50 per page
0votes
1comment
63views

Genuine versus third-party SFP/SFP+ on Extreme switches: DDMI not readable on an X620, no vendor support

The poster had free thrid-party SFP/SFP+ samples that worked on Extreme switches and asked whether to buy genuine or third-party modules. A respondent reported that on a new X620 a third-party SFP+ linked but its DDMI data could not be read, and that Extreme provides no help for problems involving…

2votes
1 answer
110views

FortiGate 500E shows This port is using a third-party transceiver: warning or error?

A FortiGate 500E displayed the message This port is using a third-party transceiver on an SFP+ port; the poster asked whta it meant and which SFP+ specification to use. There were no errors or link problems, only the log line, so the real question was whether it signals a fault, degrades support…

5votes
3comments
129views

IBM Power FC adapters: is the SFP its own FRU, and will IBM swap optics we did not buy from them

We run a couple of IBM Power boxes next to a small SAN, and I am trying to write down a sane spares policy before the next hardware maintenance renewal. The part I cannot pin down is the transceiver itself: on some adapters it looks like a field-replaceable part in its own right, on others a…

0votes
2comments
150views

NETGEAR M4300-96X with APM402XL: no NETGEAR QSFP+ optics exist, so what goes in the 40G ports

Speccing the uplinks for an M4300-96X before the order goes in, and the 40G side has turned into a dead end that I would like to sanity check with people who have actually built one. NETGEAR M4300-96X chassis APM402XL port card for the 40G QSFP+ ports planned: two 40GBASE-X runs to the neighbouring…

3votes
4comments
163views

Speccing 25G and 100G optics for NETGEAR M4500-48XF8C and M4350 when NETGEAR brands none itself

We are building out two racks and the switching is settled: a pair of M4500-48XF8C as the leaves with M4350 underneath. What is not settled is the optics BOM. NETGEAR does not put its own label on 25G or 100G modules, and I would rather not discover after delivery that the SFP28 ports dislike what…

1vote
1 answer
172views

VyOS on Supermicro SYS-1019D with Intel X722: i40e has no allow_unsupported_sfp, third-party SFP+ rejected

On a Supermicro SYS-1019D-FRN8TP running VyOS 1.4 rolling the on-board Intel X722 (i40e) did not recognise an ISP-supplied 1310/1270 nm single-fibre SFP nor other spare optics; ethtool -m returned Cannot get module EEPROM information: Invalid argument. The poster asked how to apply the well-known…

1vote
1comment
171views

Aruba Instant On 1930 shows SFP+ ports DOWN in the dashboard with third-party D-NET LX modules that pass traffic

On an Aruba 1930 (JL685A, software 2.6.0) two D-NET DN-SFP-LX modules in SFP+ ports 49 and 50 actually carried traffic, yet the web dashboard showed both ports as DOWN and, without a CLI, the poster could not check whether the modules were identified. The question was whether this was a bug, an…

0votes
1 answer
247views

Third-party optics on HPE FlexFabric 5700: no allow command, only transceiver phony-alarm-disable

The poster asked whether third-party optics can be used in an HPE FlexFabric 5700 40XG 2QSFP+ (JG896A) and whether the ProVision command allow-unsupported-transceiver exists on it. The answer clarified how Comware differs from ProVision: there is no allow-list of supported transceivers, so unlisted…

1vote
3comments
138views

Enabling a third-party transceiver on HPE FlexFabric 5900AF: no CLI switch, ask the supplier to code it for HP 5900

A FlexFabric 5900AF running Comware 7.1.035 R2208P01 reported a third-party transceiver as not supported when inserted, while the same class of modules worked in a FlexFabric 7904 on 7.1.045. The poster asked whether support could be enabled by command and whether the Comware versin mattered…

7votes
5comments
304views

Lenovo RackSwitch G8124E refuses a generic 10G SR SFP+ with UNAPPROVED - SR SFP+ is DISABLED

We pulled a pair of G8124E out of a decommissioned rack and I am rebuilding them as the aggregation layer for an internal test environment. Budget for branded optics is zero, so everything goes in with generic 10G SR modules of the type we already run elsewhere. Lenovo RackSwitch G8124E, ex-IBM…

3votes
1 answer
157views

Enabling third-party SFPs on an Aruba 2530-48G-2SFP+: allow-unsupported-transceiver from 16.02.0013

An Aruba/HPE 2530-48G-2SFP+ on firmware 16.01.0012 logged Port contains a transceiver not made by Hewlett Packard Enterprise with the advice to use onlly genuine transceivers, and refused the modules; ironically one of the rejected transceivers was HP-branded. The poster asked whether a command…