CodingBox Q&A Ask question

Questions tagged “SFP”

40 questions
15 30 50 per page
0votes
1 answer
56views

Kernel fixup for Cotsworks SFF modules with invalid EEPROM identity bytes and a bad base checksum

Some Cotsworks SFF fibre modules ship with invalid data in the first EEPROM bytes (physical ID, extended physical ID, connector type) and with checksums programmed before the fields were finalised, so the Linux phy/sfp driveer does not detect them as valid modules. A kernel fixup rewrites the three…

0votes
1 answer
64views

Kernel SFP quirk for the ODI DFP-34X-2C2 GPON ONU: force 2500BASE-X when the EEPROM does not advertise it

An ODI DFP-34X-2C2 GPON ONU SFP failed to advertise its 2500BASE-X capability because its EEPROM (or virtual EEPROM) did not provide correct speed information to the Linux sfp driver, so the interface did not run at the expected rate. A kernel patch adds a quirk to force the right speed. Hardware…

0votes
1 answer
90views

SFPTotal coding boards: read/decode/edit/write transceiver memory across many form factors with a vendor-code database

A USB coding-board product line to reprogram optical transceivers so they match different equipment vendors. Supported form factors span GBIC, SFP, SFP+, SFP28, XFP, QSFP, QSFP28, QSFP-DD plus RJ45, DAC and AOC. The software reads, decodes, edits and writes module memory, ships about 400 well-known…

1vote
2comments
79views

TP-Link T2600G-28TS SFP port shows UP but receives nothing over fibre to D-Link converters; firmware update fixed it

A T2600G-28TS (TL-SG3424) uplinked over fibre to another building using D-Link transceivers and media converters showed the SFP port UP and transmitting but never receiving packets. Restart, factory reset and other SFP ports were tried. Another user returned the switch after failing to link it to…

3votes
3comments
113views

Aruba AP-375 uplink: any way to run a Cisco BiDi SFP, or is the AP locked to approved optics?

We are pushing Wi-Fi into an outbuilding on a campus site. The only fibre going that way is a single strand, so the plan was to hang an AP-375 out there and feed it over a BiDi pair we already had on the shelf. Aruba AP-375, ArubaOS 8 Cisco BiDi SFP in the AP cage, its matching partner wavelength…

0votes
1 answer
72views

Eltex MES2324FB endlessly flaps the link with a Foxgate SFP toward an Alcatel 6224, module diagnostics show N/S

Installing a new MES2324FB at a site to replace old hardware. The uplink is 1G fiber to an Alcatel 6224, Foxgate modules from the same batch as at neighboring sites. Setup: Eltex MES2324FB, firmware 4.0.4.7, also tried 4.0.6 - no difference 1G SFP Foxgate on both ends of the link far end - Alcatel…

Russia waveadmin RU asked
5votes
1 answer
211views

Brocade 200e between Proxmox and FreeNAS: Buffer I/O error and isp0: Receive Error while all ports show online

Running a small virtualization setup: two Proxmox 6 nodes and a target on FreeNAS 11.2. While the HBAs were connected to the target directly, everything ran for months without a single error. Put a used Brocade 200e between them to avoid crossing cables, and that's when it started. two Proxmox 6…

6votes
6comments
141views

Turris Omnia pins a Luleey LL-XS2510 XPON stick to 1000baseX and ethtool never offers 2.5G

My fibre WAN runs into a Turris Omnia and I moved from the ISP box to an XPON stick to drop one hop. The stick is a 2.5G part, the Omnia cage does 2.5G, and everything still lands at 1G. Turris Omnia, Turris OS 7.0.2 HBS, kernel 5.15.148 Luleey LL-XS2510 XPON SFP, RTL960x based, DFP-34X-2C2 family…

5votes
4comments
202views

27 km span on an MES3324F: the same modules link up in an MXA-64 but Eltex takes the port to PORT_SUSPENDED

A link between two of our sites: about 27 km of single-mode fiber, MES3324F on both ends. Installed a pair of 1550 nm FANG HANG SFPs sold as 40-km modules. The link comes up, lives for a few dozen seconds, and drops, over and over, until the port gets blocked. 2 x Eltex MES3324F, firmware 4.0.7 SFP…