New Extreme 5420M-24 fibre uplink transmits but never receives: the two ends were forced to different speeds

Asked Active Viewed 65 Original language: English
3

Replacing an old Dell switch with an Extreme 5420M-24, the same SFP module that had worked in the Dell would not bring the network up: the uplink port was active with rising TX counters but RX stayed at zero, no DHCP address, no ping to the firewall, and a new SFP+ module behaved the same. Ethernet mode had been enabled with disable stacking-support.

  • Hardware: Extreme 5420M-24, Extreme X440, Dell switch, Extreme 5520
  • Transceivers: 1G SFP, SFP+ module
  • Form factor: SFP, SFP+

Symptoms / messages:

TX counters rise, RX stays zero
no DHCP over uplink

Comments 2

Accepted answer

With Extreme supprt the cause was found: one end was forced to 1000 full and the other to 10000 full; aligning the speed settings fixed it.

4 United Statestxnode67US Original (English)

Swap optics between both ends, check VLANs, and verify speed/duplex on both sides; a reader added that some optics vendors deliberately lock modules to specific switch brands.

3 United Stateslinkeng21US Original (English)