CodingBox Q&A Ask question

coaxeng

France joined 3 months ago 9 questions 17 comments

Homelab enthusiast from Lyon. Mostly SAN fabrics.

Questions

0votes
0comments
81views

Intel X710 in a Dell R740xd links with 2013 Cisco DACs (VID V02) but not 2019 ones (V03) of the same part number

Dell R740xd servers with OEM Intel X710 adapters were cabled to Cisco switches with SFP-H10GB-CU5M and SFP-H10GB-CU3M DACs. Two cables linked, five did not; the working ones carried a blank or V02 version ID (made 2013), the failing ones V03 (made 2019), all identified as SFP-10GBase-CX1 on the…

0votes
1 answer
88views

UCG-Fiber with a UACC-CM-RJ45-MG never recovers the link after the far-end Zyxel XS1930 reboots; DAC fixed it

A UCG-Fiber used a UACC-CM-RJ45-MG 10GBASE-T module (port 6, later port 7) to reach a Zyxel XS1930. Whenever the copper cable was disconnected for more than about 40 s or the Zyxel rebooted, the link never came back until the module was pulled for a minute or the gateway rebooted; forcing 10G or 1G…

2votes
3comments
42views

EdgeRouter 4 drops the WAN every 3-60 min with an Alcatel-Lucent GPON SFP: Failed to read SFP EEPROM_1 val -6

After moving a Bell fibre connection from an ER-X to an ER-4 with the ISP's Alcatel-Lucent/Nokia GPON SFP (3FE46541AA / G-010S-P) plugged directly into eth3, the WAN dropped every 3 to 60 minutes; syslog had hundreds of kernel: Failed to read SFP EEPROM1 at byte 0 val -6!! entries and SFP module…

0votes
1 answer
84views

EdgeSwitch ES-24 will not link to HP/Netgear/Juniper/Cisco over 1G SX SFPs until the peer disables auto-negotiation

Newly delivered EdgeSwitch ES-24 units linked to each other over gigabit SX SFPs, but the same modules (HP J4858B, J4858A, Avago AFBR-57M5APZ, Avaya AFBR5715PZ, Cisco) would not link ES-24 to HP ProCurve (four models) or Netgear (two models): the ES-24 showed a link light, the other side did not…

3votes
1 answer
61views

Receiver-overload warnings on a 10G SFP link: optical power is not negotiated; newer MMA2P00-AS revisions run hotter

An embedded device with a 10GbE SFP transceiver kept logging power warnings above 800 mW and occasional errors when fed by an NVIDIA/Mellanox MMA2P00-AS 10/25G transceiver over a 2 m OM3 LC patch. The poster assumed transmit power is negotiated between the two ends and asked whether a failed…