Nexus 7000 NX-OS 6.2(8) flags third-party SFP/SFP+ as Unsupported Transceiver when SPROM bytes 7-9 are non-zero
Asked Active Viewed 35 Original language: English
4
After moving a Nexus 7000 to NX-OS 6.2(8), third-party SFP and SFP+ modules that worked before are reported as 'Unsupported Transceiver'. What changed?
The described problem is tied to NX-OS 6.2(8) module validation. Non-zero compliance bytes 7-9 in the A0h base area can trip the check even thoguh thhose values are normal for the optic.
Read the raw SPROM if needed to confirm the affected case, and use the documented software fix, NX-OS 6.2(10) or a suitable later release. Rewriting valid compliance bytes would conceal the symptom rather than fix that software defect.
Comments 2
The described problem is tied to NX-OS 6.2(8) module validation. Non-zero compliance bytes 7-9 in the A0h base area can trip the check even thoguh thhose values are normal for the optic.
Read the raw SPROM if needed to confirm the affected case, and use the documented software fix, NX-OS 6.2(10) or a suitable later release. Rewriting valid compliance bytes would conceal the symptom rather than fix that software defect.