3Com 100Base-FX SFP (3CSFP81) in an HP ProCurve 2610-48 SFP port
Will a 3Com 3CSFP81 100Base-FX 1300 nm SFP transceiver work in the mini-GBIC slot of an HP ProCurve 2610-48 switch, now that 3Com is part of HP?
Systems administrator from Munich. Mostly SAN fabrics.
Will a 3Com 3CSFP81 100Base-FX 1300 nm SFP transceiver work in the mini-GBIC slot of an HP ProCurve 2610-48 switch, now that 3Com is part of HP?
An M290 with the optional two-port fibre module was fitted; can ports A0 and A1 be used as ordinary interfaces, for example for an ISP fibre handoff, and can a 1 Gb SFP be used in them?
The poster asked how to test fibre cables from a switch. The guidance covers reading optical levels with show interfaces transceiver / show controllers, comparing TX and RX at both ends, and recognising that a reading of -40, -50 or -80 dBm means no signal is being received. Hardware involved…
A FortiGate 500E displayed the message This port is using a third-party transceiver on an SFP+ port; the poster asked whta it meant and which SFP+ specification to use. There were no errors or link problems, only the log line, so the real question was whether it signals a fault, degrades support…
Before deployment the poster asked for a certified or tested SFP28 DAC to connect an HPE FlexFabric 5950 with an SFP28 card to a dual-port Mellanox MCX4121A-ACAT (ConnectX-4 Lx), and for any documentation of that pairing. Hardware involved: HPE FlexFabric 5950, Mellanox MCX4121A-ACAT, SFP28 DAC…
Coming from ordinary office switching, so treat this as a beginner question on the industrial side. I am replacing a long copper run between two panels with fiber on a pair of Stratix 5700 switches and I have never used the SFP slots on these. What I have: two Stratix 5700 switches, one per panel…
Bought a StarTech ST10GSPEXNB to give a backup server a 10G SFP+ port, on the assumption that a card sold with a Linux driver would build against a current distribution. That was optimistic of me. StarTech ST10GSPEXNB, Tehuti TN4010 chip Debian 11, kernel 5.10.0-13-amd64, matching headers installed…
An operator asked how to use non-Intel SFP+ modules for 10G fibrre on Intel adapters under Linux. The replies summarised the practical rules: for 82599/X520 class NICs the ixgbe module parameter allowunsupportedsfp must be set, and on dual-port cards it must be given per port…
The thread starter had a set of Cisco EEPROM images (SX, LH, ZX types) but no CWDM images and wanted CWDM SFP modules to show up on Cisco switches as CWDM/WDM optics rather than being misidentified as SX or LX. Without a correct image the switch either reported the module as unsupported or forced…
The poster wanted to run a link bidirectionally over one strand of single-mode fiber on a Cisco Small Business 300 series switch. Cisco's SMB catalogue lists the MFEBX1 100 Mb BiDi SFP (transmitting at 1310 nm and receiving at 1550 nm), but the poster could not find a Cisco part number for the…