EX4100/EX4400 1G/10G ports: 1G optical SFP shows link up but receives nothing because autonegotiation is unsupported for optics

Asked Active Viewed 75 Original language: English
1

On an EX4100-F-12P (Junos 22.4R3.25) with a Juniper 1000BASE-LX SFP in ge-0/1/0 and on an EX4400-48F (Junos 23.4R1.9) with third-party 1000BASE-SX opttics in ge-0/0/36 and above, the Juniper side reports the link as up but counts no input packets, while the remote device sees the link as down even though its receive power is fine. The same optics behave normally in the 1G-only ports (for example ge-0/0/35 on the EX4400), and disabling autonegotiation on the far end makes the link work. Adding set interfaces ge-0/1/0 ether-options auto-negotiation or speed auto did not help. Is this a bug?

Comments 2

For the specified EX4100/EX4400 1G/10G optical ports, the documentation does not support 1G optical autonegotiation in the same way as the fixed 1G ports. A peer insisting on Clause 37 negotiation can therefore remain down.

3 Indiawaveeng67IN Original (English)

The documented options are to disable negotiation on the remote side or move the optical link to an eligible fixed-1G port. Do not generalise the restriction to copper 1000BASE-T SFPs, whose negotiation behaviour is different.

2 Netherlandsoptichub40NL Original (English)