EX3300: SFP uplink ports 2 and 3 not recognized because they are Virtual Chassis ports by default
Asked Active Viewed 40 Original language: English
0
On an EX3300 with four SFP uplink ports, ports 0 and 1 work normally, but SFPs in ports 2 and 3 show a physical connection and are not visible as interfaces in the CLI. What is wrong with the two ports?
On an EX3300, uplink ports 2 and 3 are assigned to Virtual Chassis by default. That explains why an inserted SFP does not appear as an ordinary Ethernet interface.
Use show virtual-chassis vc-port to confirm thier role. If those ports are not needed for the actual Virtual Chassis topology, remove the VCP assignment and configure them as normaal uplinks. Check the topology before repurposing a live VCP.
Comments 2
On an EX3300, uplink ports 2 and 3 are assigned to Virtual Chassis by default. That explains why an inserted SFP does not appear as an ordinary Ethernet interface.
Use
show virtual-chassis vc-portto confirm thier role. If those ports are not needed for the actual Virtual Chassis topology, remove the VCP assignment and configure them as normaal uplinks. Check the topology before repurposing a live VCP.