Banana Pi BPI-R4 (OpenWRT) logs failed to read EEPROM: -ENXIO and module slow to respond

Asked Active Viewed 86 Original language: English
3

On a Banana Pi BPI-R4 running OpenWRT 24.10.0 an SFP module failed with kernel logs failed to read EEPROM: -ENXIO and warnings that the module was slow to respond. The internet still worked but the log filled with the error, and the poster was unsure whether it pointed to a faulty stick, a GPON quirk needing a boot delay, or an I2C/power problem on the board's SFP cage.

  • Hardware: Banana Pi BPI-R4
  • Transceivers: SFP module (suspected GPON/XPON)
  • Form factor: SFP

Symptoms / messages:

failed to read EEPROM: -ENXIO
module slow to respond

Comments 2

It is likely a GPON/XPON stick that needs a boot-delay quirk; use ethtool --dump-module-eeprom to get the vendor/product for a kernel quirk and check whether the secondary EEPROM at 0x51 (not 0x50) causes the error.

0 United Stateswavebyte8US Original (English)

A related NVMe/I2C thread had the fix that helped the poster; also verify the I2C bus with i2cdetect, power delivery and firmware.

4 United StatesedgewolfUS Original (English)