CodingBox Q&A Ask question

coaxtech75

Italy joined 12 months ago 7 questions 14 comments

Telecom integrator from Turin. Mostly ISP backbone.

Questions

0votes
1 answer
22views

Huawei 25GE ports: 10G SFP+ and short copper cables need RS-FEC enabled or the interface stays down

On Huawei switches with 25GE ports the poster asked about using SFP+ transceivers and copper cables; per the troubleshooting docs, when a non-1 m copper cable is connected to a 25GE interface the RS-FEC function must be enabled or the interface goes Down, and mixing different optical modulles at…

0votes
1 answer
57views

Kernel fixup for Cotsworks SFF modules with invalid EEPROM identity bytes and a bad base checksum

Some Cotsworks SFF fibre modules ship with invalid data in the first EEPROM bytes (physical ID, extended physical ID, connector type) and with checksums programmed before the fields were finalised, so the Linux phy/sfp driveer does not detect them as valid modules. A kernel fixup rewrites the three…

2votes
1comment
52views

TP-Link TL-SM311LM to a SkyLane SFP in a Netgear GS716T: TP-Link side up, Netgear side down, 1 Mbps throughput

A TP-Link T1700G-28TQ (V3, firmware 3.0.0) with a TL-SM311LM module was linked to a Netgear ProSafe GS716T with a SkyLane SFP85P55GE0B989 module. The TP-Link port showed 1000M with a flashing LED while the Netgear port stayed down, and throughput was about 1 Mbps; with a media converter the link…

2votes
2comments
112views

UDM Pro to US-16-150W over a 1 m Ubiquiti DAC: link light on the switch only, even with both ports forced to 1G

A UDM Pro (port 11 set to 1G) and a US-16-150W (port 17) connected by a 1 m Ubiquiti DAC (UDC-1) did not talk: the switch showed a link light, the UDM Pro showed nothing. Setting both sides to 1G and rebooting both devices did not help; reversing the cable and removing the parallel copper uplink…

Italy coaxtech75 IT asked