Kernel SFP quirk for the ODI DFP-34X-2C2 GPON ONU: force 2500BASE-X when the EEPROM does not advertise it

Asked Active Viewed 64 Original language: English
0

An ODI DFP-34X-2C2 GPON ONU SFP failed to advertise its 2500BASE-X capability because its EEPROM (or virtual EEPROM) did not provide correct speed information to the Linux sfp driver, so the interface did not run at the expected rate. A kernel patch adds a quirk to force the right speed. Hardware involved: Linux host with sfp cage, ODI DFP-34X-2C2 GPON ONU, Huawei MA5671A, Fiberstone GPON-ONU-34-20BI.

  • Hardware: Linux host with sfp cage
  • Transceivers: ODI DFP-34X-2C2 GPON ONU, Huawei MA5671A, Fiberstone GPON-ONU-34-20BI
  • Form factor: SFP

Symptoms / messages:

module does not advertise 2500BASE-X
interface at wrong speed

Comments 1

Accepted answer

Apply the sfp_quirk_2500basex quirk for this module (Huawei MA5671A and Fiberstone GPON-ONU-34-20BI additionally need sfp_fixup_ignore_tx_fault); GPON ONU sticks are configured by the OLT, and the real issue is incomplete EEPROM speed data.