CodingBox Q&A Ask question

sfpnode

China joined 4 months ago 19 questions 24 comments

ISP field engineer from Shenzhen. Mostly MikroTik and Ubiquiti.

Questions

2votes
1 answer
96views

10Gtek ASF-10G-T copper module: ethtool -m returns Operation not supported until the NIC firmware is updated

A customer with a 10Gtek ASF-10G-T 10GBASE-T transceiver could not read its EEPROM: ethtool -m ens802f0 returned Cannot get module EEPROM information: Operation not supported. The vendor attributed it to a firmware version mismatch between the NIC and the transceiver. Hardware involved: 10G NIC…

1vote
2comments
80views

TP-Link T2600G-28TS SFP port shows UP but receives nothing over fibre to D-Link converters; firmware update fixed it

A T2600G-28TS (TL-SG3424) uplinked over fibre to another building using D-Link transceivers and media converters showed the SFP port UP and transmitting but never receiving packets. Restart, factory reset and other SFP ports were tried. Another user returned the switch after failing to link it to…

China sfpnode CN asked
1vote
1comment
103views

EdgeRouter 4 logs Failed to read SFP EEPROM_1 at byte 0 val -11 with a Bell Huawei MA5671A GPON stick

An EdgeRouter 4 (EdgeOS 1.10.0) with the GPON SFP taken from a Bell Home Hub 3000 (Huawei MA5671A, SC connector, DDM readable: 50.9 C, 3.25 V, 8.87 mA, TX 1.36 mW, RX 0.02 mW) logged kernel: Failed to read SFP EEPROM1 at byte 0 val -11!! twelve times a minute although the internet worked. Removing…

6votes
6comments
210views

Third-party DWDM SFP+ stays down on an Arista 7050T with EOS 4.10.6 - anything short of patching the image?

We run a small regional network and pulled a spare 7050T out of stock to use as a DWDM aggregation box. Arista-coded DWDM optics for it quote close to the price of the switch, so we bought third-party DWDM SFP+ instead, and now the switch will not talk to them. Arista 7050T, EOS 4.10.6 generic…

1vote
1comment
171views

Aruba Instant On 1930 shows SFP+ ports DOWN in the dashboard with third-party D-NET LX modules that pass traffic

On an Aruba 1930 (JL685A, software 2.6.0) two D-NET DN-SFP-LX modules in SFP+ ports 49 and 50 actually carried traffic, yet the web dashboard showed both ports as DOWN and, without a CLI, the poster could not check whether the modules were identified. The question was whether this was a bug, an…