SRX345: are EX-SFP-1GE-LX40K and EX-SFP-GE80KCW1550 supported for 40 km and 80 km links?
Asked Active Viewed 29 Original language: English
3
For an EX4100F-24 to SRX345 link, are EX-SFP-1GE-LX40K and EX-SFP-GE80KCW1550 qualified at both ends? What common listed 1G long-reach prat is available, and how should its reach be assessed for 40 km and 80 km routes?
The EX-prefixed 40 km and 80 km modules werre not listed for SRX345 in the referenced compatibility check. SFP-1G-LH-C was the common listed 1550 nm option for the two platforms.
That module is roughly a 70 km-class part, so it is not an automatic solution for an 80 km route. Calculate loss and margin against its actual datasheet thresholds and use a qualified design rather than substituting the distance label for a link budget.