CodingBox Q&A Ask question

Questions tagged “SFP+”

75 questions
15 30 50 per page
2votes
1 answer
50views

IBM Emulex dual-port 10GbE SFP+ card hangs TrueNAS and Windows at boot and never shows an active link

A used IBM Emulex dual-port 10GbE SFP+ PCIe card (bent bracket, loose heatsink) made both TrueNAS Core and a Windows 10 PC hang for a long time during boot; the switch showed a link but neither OS saw the interface as active. Hardware involved: IBM Emulex dual-port 10GbE SFP+, Chelsio NICs, Intel…

2votes
1 answer
65views

OPNsense on a budget C3758R appliance: four ix interfaces, SFP+ ports show down with an RJ45 module

On an inexpensive firewall appliance (Intel Atom C3758R, six 1GbE igc ports and two SFP+ cages wired to the CPU) OPNsense showed four ix interfaces instead of two and the SFP+ ports stayed red/down with a copper SFP+ RJ45 module, although the link LEDs lit. ifconfig -v identified ix0/ix1 as the…

2votes
1 answer
110views

FortiGate 500E shows This port is using a third-party transceiver: warning or error?

A FortiGate 500E displayed the message This port is using a third-party transceiver on an SFP+ port; the poster asked whta it meant and which SFP+ specification to use. There were no errors or link problems, only the log line, so the real question was whether it signals a fault, degrades support…

4votes
2comments
152views

Zyxel XGS4600 SFP+ modules randomly stop transmitting after firmware 4.50; DDM shows TX power -inf and 0 mA bias

On Zyxel XGS4600 switches, 10G and 1G SFP+ transceivers (including an FS.com DWDM-SFP10G-80) intermittently stopped transmitting; only removing and reinserting the module restored the link. Transceiver statistics at that moment showed TX power -inf dBm, voltage at the 3.00 V low alarm and TX bias…

France fiberwolf FR asked
0votes
0comments
54views

Cisco-compatible CWDM SFPs that worked in PowerConnect 6024/6224 report transmit failure in an 8024F

Cisco-compatible CWDM SFP modules that had worked in Dell PowerConnect 6024 and 6224 switches produced a transmit failure error in a PowerConnect 8024F, presumably because the 8024F ports are SFP+. The poster considered Finisar FWLF1524P2Vxx modules but wanted confirmation from someone with a…

2votes
1 answer
99views

Connecting a UDM SE 10G SFP+ port to an Enterprise XG 24 SFP28 port: which DAC, and the mixed-speed limitation

The poster wanted to connect a UDM SE (10G SFP+) to an Enterprise XG 24 switch (25G SFP28) and asked whether an SFP+ DAC would work with the SFP28 port falling back to 10G, or whether an SFP28 DAC was preferable. The concern was whether the SFP28 cage would fall back to 10G with an ordinary SFP+…

1vote
2comments
55views

UniFi UNAS Pro and UNVR 10G SFP+ ports drop to 1G after firmware updates or power cycles until the module is reseated

On two sites a UNAS Pro (UniFi RJ45 SFP+ module) and a UNVR (UniFi fibre SFP+ module) dropped to 1G after every firmware update or power cycle; rebooting the device, the port or the switch did not help, only physically pulling and reinserting the module (or reseating the fibre) restored an…

2votes
2comments
144views

UniFi switches on firmware 7.2.123: SFP+ optics and DACs flap, STP flapping alerts, ports need reboot or forced 1G

After UniFi Network 10.0.140 / switch firmware 7.2.123 several operators saw SFP+ ports (UI optics, UACC-OM-MM-10G-D, MikroTik XS+DA0001 DACs, UACC-CM-RJ45-MG copper modules) flapping on US-XG-16, USW Pro Max, UDM Pro and USW-24-Pro units, with STP State Flapping alerts, ports blocked, and switches…

2votes
2comments
120views

Do DrayTek Vigor2962 and VigorSwitch G2540x take third-party SFP+ optics, or only DrayTek modules?

We are moving the office uplinks from copper to fibre and the quote that came back has DrayTek-branded optics in every line. Before I start arguing about the difference against ordinary 10G modules I would like to know whether the hardware actually cares what sits in the cage, because the…

2votes
1 answer
162views

Aruba CX 6200F: no 10G value in the speed command on port 1/1/25 with a Cisco SFP-10G-SR

We are refreshing the core of a small office and put in a pair of Aruba CX 6200F. The link between the two switches is meant to be a 10G trunk on the SFP+ uplinks, and I cannot get either box to admit that 10G exists on that port. 2x Aruba CX 6200F Switch Series, trunk on port 1/1/25 Cisco…

3votes
1 answer
72views

Aruba 2540 uplink ports 51-52 stay Down on an inter-building run while a 2530 links the same modules

I look after a two-building site and the access switches were replaced with Aruba 2540s a while back. The fibre between the buildings has not been touched, but since the swap the uplink refuses to come up. Aruba 2540 on our side, ports 51 and 52 used for the uplinks Aruba J4858D 1000SX in the 2540…

3votes
1 answer
78views

1G SFP stays dark in a DrayTek VigorSwitch FX2120 SFP+ cage while the same module links elsewhere

I look after a small office network and put in a DrayTek VigorSwitch FX2120 to get a 10G core. Both 10G links, to the router and to the NAS, came up on their own within seconds. What I cannot do is get a single 1G device onto the switch through the SFP+ cages. Switch: DrayTek VigorSwitch FX2120…

5votes
1 answer
165views

Dell DD9900 in an HA pair doesn't see the SFP on ethMa: State UP, link status NO, Cannot get module EEPROM information

I run a backup storage system in a data center. A pair of DD9900 in HA, network ports on the NDC QLogic. After a reboot or reseating the module, port ethMa stops seeing the transceiver, and it's not a one-off - it's a stable, repeating pattern. Dell DD9900, DD OS 7.2.0.95, HA configuration NDC…

Russia portrunner91 RU asked
2votes
1 answer
167views

Brocade G610 on FOS 9.x faults compatible 16G SWL optics: Mod_Inv and Speed Mismatch / Incompatible SFP

We are adding capacity to a small FC fabric and bought compatible 16G short-wave SFP+ from an optics supplier instead of paying the switch vendor price. The switch refuses them. Brocade G610, Fabric OS 9.x generic-coded 16G SWL SFP+, correct wavelength and reach according to the label Brocade-coded…

4votes
1 answer
162views

Solarflare SFN7122F under TrueNAS: card is detected, but working multimode SFP+ modules stay dark

Building a storage box at home and picked up a dual 10GbE Solarflare SFN7122F (SFC9120) because it was cheap. The card itself looks healthy, the system sees it and both ports enumerate, but not one of my existing multimode SFP+ modules will bring up a link in it. Solarflare SFN7122F, dual port…

3votes
5comments
143views

Programmer returns WRITE FAIL on an SFP+ that dumps cleanly: dead EEPROM or something blocking writes?

We recode a small batch of modules for customer hosts most months, nothing exotic: read the original page, write the vendor string the host wants, put the module in the switch and move on. One module out of the current batch refuses every write while reading back perfectly, and before I bin it I…

4votes
3comments
124views

Napatech capture SmartNICs: what actually happens with an SFP+ that is not in the qualified list

We run packet capture on a handful of Napatech cards and I am putting together the optics order for the next rack. Before spending anything I want to understand what the qualified module list actually means in practice, because the wording leaves room for interpretation. Napatech NT40E3 and NT20E3…

3votes
4comments
109views

Oracle ZFS Storage ZS3-2: only X2129A and X5562A-Z are listed for the X1109A-Z 10GbE NIC

We took over a pair of ZS3-2 controllers together with the shelves behind them, and I am the one who has to order optics before they go back into service. The controller service manual is very short on this point: it lists the NIC and HBA options, and for the 10GbE SFP+ card it names exactly two…

4votes
1 answer
181views

EX4200 reports the SFP+ EEPROM as mis-programmed after a Junos upgrade while an MX960 still shows DOM

We run a handful of 80 km DWDM spans off EX4200s with third-party optics on both ends, because the vendor-branded DWDM parts were never going to fit the budget. That was fine for years. After the EX boxes were moved to Junos 12.3 the optics still sit in the same ports and the spans still exist, but…

6votes
6comments
209views

Third-party DWDM SFP+ stays down on an Arista 7050T with EOS 4.10.6 - anything short of patching the image?

We run a small regional network and pulled a spare 7050T out of stock to use as a DWDM aggregation box. Arista-coded DWDM optics for it quote close to the price of the switch, so we bought third-party DWDM SFP+ instead, and now the switch will not talk to them. Arista 7050T, EOS 4.10.6 generic…

5votes
6comments
78views

Third-party SFP+ optics stay down on a second-hand DCS-7150S-24: is the enable3px flash file still an option?

I picked up a couple of second-hand Arista switches for the lab and ran straight into the optics gate. Arista-coded modules link up, passive DAC cables link up, and anything third-party leaves the port down. The lab side: DCS-7150S-24, bought used, no support contract and no account team behind me…

8votes
1 answer
163views

About 15% packet loss through an S+RJ10 copper SFP+ on a CRS518-16XS-2XQ while the direct 100G path is clean

We push traffic from a lab server into a CRS518-16XS-2XQ over a 100G QSFP28 uplink, and it leaves the switch through a MikroTik S+RJ10 copper SFP+ into a plain 1G RJ45 host. The receiving side is missing a large share of the packets and I cannot pin it on anything obvious. Setup: MikroTik…