2votes
1 answer
284views

ethtool -m on Intel X722 fails: Module EEPROM memory read not supported, please update the NVM image

On an Intel S2600WFT board the X722 10GbE SFP+ controller (rev 09, NVM 3.31 0x80000d31 1.1767.0) refused ethtool -m with Cannot get module EEPROM information: Invalid argument, and the kernel logged Module EEPROM memory read not supported. Please update the NVM image. The behaviour was identical…

1vote
1 answer
172views

VyOS on Supermicro SYS-1019D with Intel X722: i40e has no allow_unsupported_sfp, third-party SFP+ rejected

On a Supermicro SYS-1019D-FRN8TP running VyOS 1.4 rolling the on-board Intel X722 (i40e) did not recognise an ISP-supplied 1310/1270 nm single-fibre SFP nor other spare optics; ethtool -m returned Cannot get module EEPROM information: Invalid argument. The poster asked how to apply the well-known…

1vote
1 answer
59views

i40e refuses to load with Fiberxon 10G SFP+ on X710: no allow-unsupported-SFP option

The poster's Intel Ethernet Converged Network Adapter X710 would not come up with third-party Fiberxon 10G SFP+ modules: the i40e driver, version 1.2.48, refused to initialise and reported "The driver failed to load because unsupported module type was detected." They asked how to switch on an…

5votes
1 answer
274views

XL710-QDA2 disables Rx/Tx with non-Intel QSFP+ cables: "unsupported SFP+ module type" in i40e

The poster compiled and loaded i40e 3.4.2 on Ubuntu 16.04 for an Intel XL710-QDA2 dual-port 40GbE adapter. The driver loaded fine, but as soon as non-Intel QSFP+ cables were attached dmesg reported "Rx/Tx is disabled on this device because an unsupported SFP+ module type was detected." and no link…

6votes
3comments
120views

Finisar FCLF8521P2BTL 1000BASE-T SFP rejected by Intel X710-DA2 despite feature matrix listing

The poster wanted to use a Finisar FCLF8521P2BTL 1000BASE-T copper SFP in an Intel X710-DA2 running NVM 7.1. Intel's X710/XXV710/XL710 Feature Support Matrix (rev. 3.4, Nov 2019, doc 332191-024) lists single-speed SFP 1GBASE-T transceivers with support limited to Finisar FCLF-8521-3, Kinnex A…