Intel X710-DA4 with FIBO 850 nm SFP+: transmitter stays off (-40 dBm TX) while the same modules work in an 82599ES
Four FIBO 850 nm SFP+ modules in an Intel X710-DA4 (i40e 2.3.2-k, firmware 6.01 0x800035ce) are recognised and show receive power (about -2.5 dBm), but they never transmit: ethtool -m reports laser output 0.0001 mW / -40 dBm, ethtool shows Speed Unknown and Link detected: no. The very same modules work in a dual-port Intel 82599ES card. Why does the X710 keep them dark?
Comments 2
The successful replacement in the repoorted X710 case was genuine Intel SFP+ optics. Working receive-power diagnostics did not prve that the firmware would enable the transmitter for the FIBO modules.
The same module working in an 82599ES is not proof of X710 acceptance. Check the X710-qualified list and coding for the installed firmware rather than assuming all Intel adapters apply identical module validation.