MX10003: SFPP-10G-ER-C (740-031983) needs the MAM1Q00A-QSA adapter despite the HCL wording

Asked Active Viewed 64 Original language: English
1

Juniper's hardware compatibility page lists SFPP-10G-ER-C (740-031983) for the MX10003 without the usual noe about a QSA adapter. Can this 40 km 10G ER module be used directtly in the MX10003 without the MAM1Q00A-QSA?

Comments 2

SFPP-10G-ER-C is an SFP+ optic, while the relevant MX10003 line-card cages are QSFP form factor. The MAM1Q00A-QSA adapter is required for that physical conversion.

3 IndiasfpopsIN Original (English)

A compatibility-table entry can omit the adapter ntoe without changing the connector. Check the complete port/adapter/optic combination rather than expecting the SFP+ module to plug directly into the larger cage.

1 GermanywavesmithDE Original (English)