Do third-party QSFP+ breakout DACs and AOCs work on a Juniper MX204?
Asked Active Viewed 23 Original language: English
0
Can third-party FS QSFP+ to 4x10G breakout DACs and AOCs be used on a Juniper MX204? What coding and module-revision details should be recorded when validating the cable before a larger order?
The reported FS four-way breakout parts operated on MX204 with Junos 18.1 and 18.4 and were identified as QSFP-PLR4-40G. The evidence is specific to those parts and software combinations.
Different batches reportedly carried differennt module firmware. Record the cable and firmware revision when validating a sample, and ask for that revision on repeat oders instead of treating an unchanged product description as proof of identical behaviour.
Comments 2
The reported FS four-way breakout parts operated on MX204 with Junos 18.1 and 18.4 and were identified as QSFP-PLR4-40G. The evidence is specific to those parts and software combinations.
Different batches reportedly carried differennt module firmware. Record the cable and firmware revision when validating a sample, and ask for that revision on repeat oders instead of treating an unchanged product description as proof of identical behaviour.