CodingBox Q&A Ask question

Questions tagged “Cisco”

56 questions
15 30 50 per page
2votes
1 answer
34views

Cisco doc: troubleshooting an unsupported transceiver in a Catalyst 3850 network module

Cisco troubleshooting document: inserting certain SFPs (for example GLC-SX-MMD or third-party modules) into a Catalyst 3850 C3850-NM sub-module produces %PLATFORMPM-6-MODULEERRDISABLE: The inserted SFP module ... is not supported and %PM-4-ERRDISABLE: gbic-invalid ... putting ... in err-disable…

2votes
1 answer
100views

Cisco module signature: bytes 96-127 must match the serial number or a recoded SFP is rejected

Discussion of why re-coded modules fail Cisco validation: Cisco SFPs carry a unique signature tied to each serial number in bytes 96-127, and editing vendor name or serial makes the signature no longer match, so the switch rejects the module unless the signature is regenerated. Hardware involved…

0votes
0comments
151views

Intel X710 in a Dell R740xd links with 2013 Cisco DACs (VID V02) but not 2019 ones (V03) of the same part number

Dell R740xd servers with OEM Intel X710 adapters were cabled to Cisco switches with SFP-H10GB-CU5M and SFP-H10GB-CU3M DACs. Two cables linked, five did not; the working ones carried a blank or V02 version ID (made 2013), the failing ones V03 (made 2019), all identified as SFP-10GBase-CX1 on the…

0votes
0comments
109views

Dell S5212F-ON to Cisco C9500-48Y4C: dual-coded FS SFP28 DACs stay protocol down while 2 m Cisco/Cisco cables link

Between VxRail Dell S5212F-ON TOR switches and Cisco C9500-48Y4C switches, FS.com SFP28 DACs behaved inconsistently: a 5 m cable custom-coded Cisco on one end and Dell on the other came Line Up, Protocol down; a 2 m Cisco/Cisco-coded cable linked; a 3 m cable would not link even with the 2 m…

2votes
1 answer
109views

MikroTik CSS610 to Cisco Nexus 5596: transceivers detected, no link, four bad fibre patch cords

A MikroTik CSS610-8P-2S+ (SwOS Lite) needed to connect its SFP+ ports to a Cisco Nexus 5596UP. The ports showed the transceivers in the web UI but no link, after trying several fibre cables and transceivers. The switch web UI listed vendor and type for each module, yet the port stayed at no-link…

4votes
1 answer
102views

CSCwo18785: 'ERROR: The transceiver doesn't support this speed' with a third-party 200G DAC on Nexus 9332D-GX2B

The poster, validating their product against Cisco Nexus 9000 switches (a Nexus C9332D-GX2B chassis), is blocked by bug CSCwo18785: configuring 200G on a QSFP-200G DAC fails with 'ERROR: The transceiver doesn't support this speed'. The cable is a Mellanox MCP1650-H002E26 200GbE DAC; connected…

2votes
1 answer
225views

CBS350 SFP-10G-LR link only comes up when the TX fiber is inserted before RX; faulty transceiver pair

While rolling out single-mode fiber between Cisco CBS350-8MGP-2X switches (firmware 3.4.0.17) with SFP-10G-LR modules, the poster hit strange behaviour: the link only comes up if the duplex LC connector is split and the TX fiber is inserted first, then the RX fiber. Inserting the joined LC…

4votes
2comments
314views

Catalyst C9300X-24Y resets FEC to auto when an SFP-H25G-CU2M DAC is inserted, breaking the link to a FortiGate

The poster connects a Cisco Catalyst C9300X-24Y to a FortiGate firewall with a 25G SFP-H25G-CU2M DAC. Whenever the DAC is inserted the switch logs '%PLATFORMPM-6-MODULEINSERTED: SFP module inserted with interface name Twe1/0/23' followed by '%PLATFORMPM-6-DIFFERENTMODULEINSERTED: Warning: SFP…

1vote
2comments
127views

Checking from 'show idprom' whether an old CISCO-FINISAR 1000BASE-LX SFP can be reused in a Catalyst 9300-M

Before replacing an old switch with a Cisco Catalyst 9300-M, the poster wanted to know whetther the existing SFP could be reused and posted the 'show idprom interface gigabitEthernet 1/1/1' output: Vendor Name CISCO-FINISAR, Vendor Part Number FTLF1318P2BCL-C3, serial FNS15510U5B, 1310 nm, single…

0votes
1 answer
115views

Nexus 93108TC-FX3P: QSFP-100G-CU1M link only comes up when speed is set before inserting the cable

Two Cisco Nexus 93108TC-FX3P switches on NX-OS 9.3(11) are connected with genuine QSFP-100G-CU1M DACs but the link never comes up. The compatibility matrix says the cable is supported from NX-OS 9.3.5. The port config is a plain 'switchport mode trunk' / 'no shutdown', and 'show interface eth1/54…

2votes
1 answer
310views

Does 'service unsupported-transceiver' still work for third-party optics on Catalyst 9300 with IOS XE Everest?

The poster asked whether anyone had used third-party optcis in a Cisco Catalyst 9300 series switch running IOS XE Everest (16.x), and specifically whether the hidden global command 'service unsupported-transceiver', long used on older Catalyst platforms to accept non-Cisco SFPs, still functions on…

4votes
1 answer
112views

Catalyst 3750-X C3KX-NM-10G module reports GLC-SX-MMD as 'Not Present' in some slots

Two Cisco Catalyst 3750-X switches (WS-C3750X-24P-L and WS-C3750X-48P-L) run identical code. A Cisco GLC-SX-MMD is detected normlly in Gi1/1/1 of the first switch, but the second switch reports 'media type is Not Present' with 'link type is force-up' on Gi1/1/1, and 'show idprom interface Gi 1/1/1'…