CRS312 to UniFi USW-Pro-48 could only link at 1G after a RouterOS upgrade; the RouterBOARD firmware had not been updated

A MikroTik CRS312-4C+8XG (RouterOS 7.13.4) and a Ubiquiti USW-Pro-48 (6.6.61) over 20 m OM3 with SR 850 nm SFP+ optics would only negotiate 1G full duplex; 10G attempts failed with no link and occasional Rx Fault on the UniFi side. Several fibre and transceiver combinations were tested and RouterOS…

1vote
2comments
127views

Checking from 'show idprom' whether an old CISCO-FINISAR 1000BASE-LX SFP can be reused in a Catalyst 9300-M

Before replacing an old switch with a Cisco Catalyst 9300-M, the poster wanted to know whetther the existing SFP could be reused and posted the 'show idprom interface gigabitEthernet 1/1/1' output: Vendor Name CISCO-FINISAR, Vendor Part Number FTLF1318P2BCL-C3, serial FNS15510U5B, 1310 nm, single…