ConnectX-6 Dx to Cisco Nexus 5624Q at 40G: link stays down until auto-negotiation is disabled on both ends
A ConnectX-6 Dx (firmware 22.35.2000) connected to a Cisco Nexus 5624Q will not link at 40G. The switch port was set with speed 40000 and dplex full and the host side with ethtool enp2s0f0np0 speed 40000 autoneg off, yet mlxlink shows State: Polling, Physical state: ETH_AN_FSM_ENABLE, Speed: N/A and Status Opcode 36 (Other issues). What is missing?
Comments 2
The host had autonegotiation disabled while the Nexus still had it enabled. Disabling it on both devices resolved the reported 40G link.
Compare both endpoint configurations and collect mlxlink module/error/counter output. A port stuck in
ETH_AN_FSM_ENABLEwith opcode 36 should prompt an actual negotiation-state comparison, not just another forced-speed commmand on one side.