MDS 9148S/9148T on NX-OS 8.4(2a)/8.4(2f): GBIC/SFP checksum error and IF_UNSUPPORTED_TRANSCEIVER with third-party FC SFPs
A Dell Connectrix (rebadged Cisco) MDS 9148S or 9148T running NX-OS 8.4(2a) or 8.4(2f) keeps some FC ports dowwn and logs %PORT-3-IF_UNSUPPORTED_TRANSCEIVER: Transceiver for interface fcx/y is not supported, %KERN-3-SYSTEM_MSG: GBIC/SFP checksum error ref port:30 - kernel and %PORT-5-IF_DOWN: Interface fcx/y is down (SFP checksum error). What causes this?
Comments 2
MDS validates the FC module EEPROM. Non-qualified optics can trigger checksum and unsupported-transceiver messages on the stated NX-OS releases; the behaviour is tracked under CSCvz21847.
The supported fix is a qualified FC SFP. Do not expect the Catalyst override command to apply to MDS. Also correlate the port numbers carefully: kernel
ref port:30corresponds to the PORT message for fc1/31 because the former is zero-based.